FUNCTION OF MAIN COMPONENTS
The components have the following functions:
| Component | Function |
|---|---|
| Rear Center Ultrasonic Sensor | Detects the distance between the vehicle and an obstacle. |
| No. 1 Clearance Warning Buzzer | Sounds to inform the driver according to the distance to the obstacle. |
| Clearance Warning ECU Assembly | ·
Judges the approximate distance between the vehicle and an obstacle based on signals from the ultrasonic sensors. ·
Sounds the No. 1 clearance warning buzzer. |
| Back Sonar or Clearance Sonar Switch Assembly | Operating this switch allows the operation of Toyota parking assist-sensor system to be enabled or disabled. |
| Park/Neutral Position Switch Assembly | Transmits the shift position signal to the clearance warning ECU assembly. |
OPERATING CONDITION
The operating conditions of the ultrasonic sensors are as follows:
| Installation Position | Operating Condition |
|---|---|
| Rear Center | ·
Engine switch is On (IG). ·
Back sonar or clearance sonar switch assembly is on. ·
Shift lever is in R. |
SYSTEM CONTROL
No. 1 Clearance Warning Buzzer
The on and off times of the No. 1 clearance warning buzzer vary as shown in the table below, depending on the distance between the obstacle and the ultrasonic sensor:
| Ultrasonic Sensor | Obstacle Distance [mm (in.)] | Off Time (ms) | On Time (ms) | |
|---|---|---|---|---|
| Detection Level | Longest | 1500 +/- 150 to 650 +/- 70
(59.1 +/- 5.91 to 25.6 +/- 2.76) |
500 +/- 50 | 200 +/- 20 |
| Long | 650 +/- 70 to 500 +/- 50
(25.6 +/- 2.76 to 19.7 +/- 1.97) |
200 +/- 20 | 200 +/- 20 | |
| Middle | 500 +/- 50 to 400 +/- 40
(19.7 +/- 1.97 to 15.7 +/- 1.57) |
100 +/- 10 | 100 +/- 10 | |
| Short | 400 +/- 40 or less
(15.7 +/- 1.57 or less) |
0 | Continuous | |
When a malfunction is detected, the No. 1 clearance warning buzzer continues to sound as shown in the illustration.
Detection Area
The detection areas of the ultrasonic sensors are as shown in the following illustration.
These detection areas are applicable when positioning a 60 mm (2.36 in.) diameter pole parallel or perpendicular to the ground. The ranges vary depending on the measuring method and type of obstacle.
| *a | Wall | *b | Approximately 1620 mm (63.8 in.) |
| *c | Approximately 1000 mm (39.4 in.) | *d | Approximately 1500 mm (59.1 in.) |
| *e | Approximately 435 mm (17.1 in.) | *f | Approximately 100 mm (3.9 in.) |
| *g | The illustrations shown are examples only. | - | - |
|
Detection Area | - | - |
| *a | Wall | *b | Approximately 1590 mm (62.6 in.) |
| *c | Approximately 1000 mm (39.4 in.) | *d | Approximately 1500 mm (59.1 in.) |
| *e | Approximately 440 mm (17.3 in.) | *f | Approximately 100 mm (3.9 in.) |
| *g | The illustrations shown are examples only. | - | - |
|
Detection Area | - | - |