CONSTRUCTION
Multi-Flow (MF)-IV Sub-cool Condenser (for TMMIN Made)
A sub-cool condenser is used. This is a multi-flow condenser consisting of 3 portions: a condensing portion, a super-cooling portion and a gas-liquid separator (modulator) all integrated together. This cooler condenser assembly uses a sub-cool cycle for its cooling cycle system to improve heat-exchanging efficiency.
Global Inner-fin Condenser (GIC) (for TMT Made)
A Global Inner-fin Condenser (GIC) is provided. This condenser has tubes with high-density inner fins, and outer fins which allow the use of thinner cores, contributing to the efficiency of cooling performance.
| *1 | Tube (Inner Fin) | *2 | Outer Fin |
| *3 | Fin Louver | - | - |
| *a | A-A Cross Section | - | - |
The cooler condenser assembly consists of 2 cooling portions: a condensing portion and a super-cooling portion. These portions are integrated with a gas-liquid separator (modulator). This cooler condenser assembly uses a sub-cool cycle that offers excellent heat-exchange performance.
Sub-cool Cycle
In the sub-cool cycle, after the refrigerant passes through the condensing portion of the cooler condenser assembly, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the No. 1 cooler evaporator sub-assembly in an almost completely liquefied state.
| *1 | Condensing Portion | *2 | Super-cooling Portion |
| *3 | Filter | *4 | Desiccant |
| *5 | Modulator | - | - |
| *a | The illustrations shown are examples only. | - | - |
|
Gaseous Refrigerant |
|
Liquid Refrigerant |