Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2018.01
NM30M0E _58 Vehicle Interior _018278 HEATING / AIR CONDITIONING _0090351 AIR CONDITIONING SYSTEM CO CONTROL F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  CONTROL  AIR CONDITIONING CONTROL  


FUNCTION OF MAIN COMPONENTS


a.

The main components of the air conditioning system have the following functions:

Component Function
Air Conditioning Control Assembly Allows operation and adjustment of the air conditioning system via switches.
Air Conditioning Amplifier Assembly Transmits and receives data to and from the switches and sensors, and controls the air conditioning system.
Cooler Compressor Assembly A compact and lightweight 10-cylinder swash plate type cooler compressor assembly is used.
Blower Motor with Fan Sub-assembly The fan blades are thin, and improve air flow inside the blower fan, contributing to the reduction of noise.
Cooler Condenser Assembly A Global Inner-fin Condenser (GIC) is used to improve heat exchange efficiency.
Heater Radiator Unit Sub-assembly A Straight Flow Aluminum (SFA)-II heater radiator is used for compactness and high performance.
No. 1 Cooler Evaporator Sub-assembly A Beneficial Refrigerant Stream (BRS) evaporator is used for efficiency of the refrigerant flow.
No. 1 Cooler Thermistor Detects the temperature of the fins of the No. 1 cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly.
Ambient Temperature Sensor (Thermistor Assembly) Detects ambient temperature and outputs it to the combination meter assembly.
Cooler (Room Temp. Sensor) Thermistor* Detects room temperature and outputs it to the air conditioning amplifier assembly.
Cooler (Solar Sensor) Thermistor* Detects the changes in the amount of solar energy and outputs them to the air conditioning amplifier assembly.
Air Outlet Servo Motor (Mode Damper Servo Sub-assembly)* Receives the input of the operation signals from the mode selector switch, operates the motor, and opens and closes the mode damper.
Air Mix Servo Motor (Air Mix Damper Servo Sub-assembly)* Receives the input of temperature setting dial signals, operates the motor, and opens and closes the air mix damper.
Air Inlet Servo Motor (Recirculation Damper Servo Sub-assembly) Receives the input of the operation signals from the fresh-air/recirculation selector switch, operates the motor, and opens and closes the fresh-air/ recirculation damper.
Clean Air Filter Removes particles to provide a comfortable interior space.
Air Conditioning Pressure Sensor Detects the refrigerant pressure and sends the data to the air conditioning amplifier assembly.
ECM Regulates the engine speed and then turns on or off the MG CLT relay, in response to signals from the air conditioning amplifier assembly.

HINT:

*: Models with automatic air conditioning system




SYSTEM CONTROL


a.

The air conditioning system uses the following controls:

Control Outline Air Conditioning Type
Automatic Manual
Neural Network Control This control is capable of effecting complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input or output relationship that is similar to a human brain. ○ -
Outlet Air Temperature Control After receiving the signals from the sensors and the temperature control switching setting, then it uses a prescribed formula to calculate the required outlet air temperature, and regulate the servomotors and the blower motor with fan sub-assembly. This outlet temperature is required in order to maintain the set temperature in a stable manner. ○ -
Blower Control Manual Control Sets the blower speed according to operation of the blower switch. ○ ○
Automatic Control This function controls the operation of the blower motor with fan sub-assembly in accordance with the signals from the No. 1 cooler thermistor, the cooler (room temp. sensor) thermistor and the cooler (solar sensor) thermistor. In addition, it protects the blower motor control from the sudden drive current that occurs when the blower motor with fan sub-assembly is activated. ○ -
Air Outlet Control Manual Control Changes the air outlet in accordance with the selected position of the mode select switch. ○ ○
Automatic Control Controls the air outlet mode to switch to FACE and BI-LEVEL in accordance with the required outlet air temperature when the AUTO switch has been turned ON. ○ -
Compressor Control When the AUTO switch is turned ON, the MG CLT relay is activated automatically to engage the compressor. ○ -
Diagnosis A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier assembly detects a problem with the air conditioning system. ○ ○


b.

Neural Network Control

i.

Previously, in automatic air conditioning systems without neural network control, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly. The air conditioning amplifier assembly can then effect control to provide enhanced air conditioning comfort.


ii.

The neural network control consists of neurons in the input layer, intermediate layer, and output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume, and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor with fan sub-assembly in accordance with the control volumes that have been calculated by the neural network control.

Y100703E14
2.833,0.167 4.031,0.354 1.198,0.188 10 false Intermediate Layer 3.854,0.344 4.667,0.521 0.813,0.177 10 false Output Layer 4.229,0.771 5.896,0.958 1.667,0.188 10 false Target Output Temperature 2.083,0.323 2.833,0.51 0.75,0.188 10 false Input Layer 1.208,0.719 2.552,0.906 1.344,0.188 10 false Ambient Temperature 1.406,1.25 2.615,1.427 1.208,0.177 10 false Amount of Sunlight 1.385,1.76 2.583,1.948 1.198,0.188 10 false Room Temperature 2.5,2.698 2.979,2.865 0.479,0.167 10 false Control 2.135,3.115 3.281,3.302 1.146,0.188 10 false Neural Networking 2.323,3.552 3.146,3.917 0.823,0.365 10 false Target Outlet Temperature 2.125,4.281 3.313,4.615 1.188,0.333 10 false Amount of Sunlight Correction 2.125,6.052 2.917,6.219 0.792,0.167 10 false Outlet Mode 2.125,5.073 2.969,5.406 0.844,0.333 10 false Target Airflow Volume 2.135,6.844 2.823,7.01 0.688,0.167 10 false Inlet Mode 2.125,7.469 3.104,7.833 0.979,0.365 10 false Electric Inverter Compressor 3.646,3.938 4.896,4.281 1.25,0.344 10 false Temperature Control Correction 3.646,5.063 5.135,5.406 1.49,0.344 10 false Various Types of Airflow Volume Corrections 3.646,5.885 4.708,6.219 1.063,0.333 10 false Various Types of Corrections 3.656,6.667 4.719,7 1.063,0.333 10 false Various Types of Corrections 0.313,3.5 1.354,3.698 1.042,0.198 10 false Input Processing 0.292,4.563 1.094,4.917 0.802,0.354 10 false Temperature Setting 0.292,5.906 1.104,6.104 0.813,0.198 10 false Sensor Input 0.292,7.167 1.104,7.354 0.813,0.188 10 false Switch Input 5.5,3.333 6.688,3.531 1.188,0.198 10 false Output Processing 5.521,3.896 6.448,4.271 0.927,0.375 10 false Air Mix Control Damper 5.521,5.885 6.365,6.25 0.844,0.365 10 false Mode Control Damper 5.521,5 6.698,5.365 1.177,0.365 10 false Blower Motor with Fan Sub-assembly 5.521,6.635 6.479,6.99 0.958,0.354 10 false Air Inlet Control Damper 5.521,7.427 6.51,7.771 0.99,0.344 10 false Electric Inverter Compressor 1.031,8.406 3.042,8.594 2.01,0.188 10 false : Neural network operation range




DIAGNOSIS


a.

The air conditioning amplifier assembly has a diagnosis function. It stores any operation failures in the memory in the form of Diagnostic Trouble Codes (DTCs). For details, refer to the Repair Manual.