POWER WINDOW OPERATION IN FAIL-SAFE MODE
If the pulse sensor built into the power window regulator motor malfunctions, the power window control system enters fail-safe mode.
The power window control system prohibits the following power window operations when the pulse sensor for the jam protection function has problems and the window position or the learned value is abnormal.
| Power Window Operation | Condition | |
|---|---|---|
| Ignition switch ON | Ignition switch off | |
| Manual up (Driver side door window) | X | - |
| Manual down (Driver side door window) | ○ | - |
| Auto up (Driver side door window)
(hold switch at auto up position) |
○*1 | - |
| Auto up (Driver side door window) | X | - |
| Auto down (Driver side door window) | X | - |
○: Operates
X: Operation prohibited
*1: Operates in manual mode without jam protection
Fail-safe deactivation condition
When the pulse sensor is normal, to deactivate fail-safe mode, pull up the power window switch to the auto up position and hold it for at least 1 second to fully close the window from the fully open position. As a result, the auto up/down function will return.
Initialization failure
During initialization of the power window regulator motor ECU, when the window position or initialization complete status cannot be properly read from the EEPROM, the power window control system prohibits the operations as follows:
| Power Window Operation | Condition | |
|---|---|---|
| Ignition switch ON | Ignition switch off | |
| Manual up (Driver side door window) | X | - |
| Manual down (Driver side door window) | ○ | - |
| Auto up (Driver side door window)
(hold switch at auto up position) |
○*1 | - |
| Auto up (Driver side door window) | X | - |
| Auto down (Driver side door window) | X | - |
○: Operates
X: Operation prohibited
*1: Operates in manual mode without jam protection