DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler (room temperature sensor) thermistor | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F) |
Actual ambient temperature displayed | - |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | - |
| Solar Sensor (D Side) | Cooler (solar sensor) thermistor | Min.: 0
Max.: 255 |
Cooler (solar sensor) thermistor value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | - |
| Set Temperature (D Side) | Set temperature | Min.: MAX COLD
Max.: MAX HOT |
Set temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level | Min.: 0
Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Air Mix Servo Targ Pulse(D) | Air mix damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
MAX COLD: 257 (pulse)
MAX HOT: 183 (pulse) |
- |
| Air Mix Servo Actual Pulse(D) | Air mix damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
MAX COLD: 257 (pulse)
MAX HOT: 183 (pulse) |
- |
| Air Outlet Servo Pulse (D) | Mode damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
FACE: 316 (pulse)
B/L: 301 (pulse) FOOT: 278 (pulse) FOOT/DEF: 267 (pulse) DEF: 252 (pulse) |
- |
| Air Outlet Servo Actu Pulse(D) | Mode damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
FACE: 316 (pulse)
B/L: 301 (pulse) FOOT: 278 (pulse) FOOT/DEF: 267 (pulse) DEF: 252 (pulse) |
- |
| Air Inlet Damper Targ Pulse | Recirculation damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
RECIRCULATION: 255 (pulse)
FRESH: 270 (pulse) |
- |
| Air Inlet Damper Actual Pulse | Recirculation damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
RECIRCULATION: 255 (pulse)
FRESH: 270 (pulse) |
- |
| Refrigerant Gas Type | Refrigerant gas type | R134a, 1234yf | Refrigerant gas type displayed | - |
| Number of Trouble Codes | Number of trouble codes | Min.: 0
Max.: 255 |
Number of DTCs displayed | - |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0
Max.: 31 |
- |
| Magnetic Clutch Relay | MG CLT relay | OFF, ON | - |
| Defogger Relay (Rear) | Defogger relay | OFF, ON | - |
| Air Mix Servo Targ Pulse(D) | Air mix damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 183 and 257 pulses |
| Air Outlet Servo Pulse (D) | Mode damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 252 and 316 pulses |
| Air Inlet Damper Targ Pulse | Recirculation damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 255 and 270 pulses |