This circuit is the power source circuit for the combination meter assembly. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.
Inspect the fuses of circuits related to this system before performing the following procedure.
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
Disconnect the combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F38-21 (ED) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| F38-39 (IG+) - Body ground | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |
| F38-40 (B) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG