88515
1.INSTALL NO. 1 EXPANSION VALVE
Apply sufficient compressor oil to 2 new O-rings and fitting surfaces of the No. 1 expansion valve.
ND-OIL 8 or equivalent
Install the 2 O-rings onto the No. 1 cooler evaporator sub-assembly.
Using a 4 mm hexagon wrench, install the No. 1 expansion valve with the 2 hexagon bolts.
88706A
2.CONNECT LIQUID TUBE SUB-ASSEMBLY A
88712
3.CONNECT NO. 1 COOLER REFRIGERANT SUCTION HOSE
Remove the vinyl tape from the No. 1 cooler refrigerant suction hose and the connecting portion of the unit.
Apply sufficient compressor oil to a new O-ring and connecting part of the No. 1 cooler refrigerant suction hose.
ND-OIL 8 or equivalent
Install the O-ring onto the No. 1 cooler refrigerant suction hose.
Connect the No. 1 cooler refrigerant suction hose.
Turn the hook connector in the direction indicated by the arrow in the illustration.
Insert the pipe joints securely into the fitting holes and tighten a new bolt.
4.CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
5.WARM UP ENGINE
6.INSPECT FOR REFRIGERANT LEAK