Home › Engine / Hybrid System › 1NZ-FE COOLING › RADIATOR › 2013.08–2016.10
RM30M0E _51 Engine / Hybrid System _017081 1NZ-FE COOLING _0090207 RADIATOR G

1NZ-FE COOLING  RADIATOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 16520A 1.INSPECT WATER FILLER CAP SUB-ASSEMBLY

a.
A288563E01
0.448,1.167 0.604,1.365 0.156,0.198 10 false 1 0.688,1.406 0.844,1.604 0.156,0.198 10 false 2 0.958,1.646 1.115,1.844 0.156,0.198 10 false 3 2.677,1.385 2.833,1.583 0.156,0.198 10 false 4

Visually check the water filler cap sub-assembly.

i.

If there are water stains or foreign matter on rubber packing 1, 2 or 3, clean the part(s) with water and finger scouring.


ii.

Check that rubber packings 1, 2 and 3 are not deformed, cracked or swollen.


iii.

Check that rubber packings 3 and 4 are not stuck together.

If necessary, replace the water filler cap sub-assembly.



b.
A104601C10
0.417,0.906 0.552,1.563 true 1.667,0.802 1.927,0.49 false 1.365,1.042 1.563,1.208 0.198,0.167 10 true *b 1.948,0.375 2.177,0.573 0.229,0.198 10 false *a 0.5,1.583 0.667,1.729 0.167,0.146 10 false *1
*1 Water Filler Cap Sub-assembly
*a Radiator Cap Tester
*b 30° or more


Measure the valve opening pressure.

i.

Apply engine coolant to rubber packings 2 and 3.


ii.

Install the water filler cap sub-assembly to the radiator cap tester.


iii.

Pump the radiator cap tester several times, and check the maximum pressure.

Pumping speed:

1 pump per second


NOTICE:

Using the radiator cap tester, tilt it to more than 30 degrees.


HINT:

Even if the water filler cap sub-assembly cannot maintain the maximum pressure, it is not a defect.


Judgment Criteria:
Item Specified Condition
Standard value
(for brand-new water filler cap sub-assembly)
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
Minimum standard value
(after using water filler cap sub-assembly)
78.5 kPa (0.8 kgf/cm2, 11.4 psi)


If the maximum pressure is less than the specified pressure for the minimum standard value, replace the water filler cap sub-assembly.