28100
1.INSPECT STARTER ASSEMBLY
As a large electric current passes through the cable during this inspection, a thick cable must be used.
If not, the cable may became hot and cause injury.
Perform each of the following tests within 3 to 5 seconds to prevent the coil from burning out.
Perform a pull-in test.
Remove the nut to disconnect the lead wire from the terminal C.
| *a | Starter Body |
| *b | Terminal C |
| *c | Terminal 50 |
Connect the battery to the magnet starter switch assembly as shown in the illustration. Check that the clutch pinion gear moves outward.
If the clutch pinion gear does not move outward, replace the magnet starter switch assembly.
Perform a holding test.
| *a | Starter Body |
| *b | Terminal C |
| *c | Terminal 50 |
Check that the pinion gear does not return inward after the lead is disconnected from the terminal C.
If the clutch pinion gear returns inward, replace the magnet starter switch assembly.
Check return operation.
| *a | Starter Body |
| *b | Terminal C |
| *c | Terminal 50 |
Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear moves inward.
If the clutch pinion gear does not move inward, replace the magnet starter switch assembly.
Perform a no-load performance test.
Connect the lead wire to terminal C with the nut.
Clamp the starter assembly in a vise between aluminum plates.
Ensure that the starter is secured in the vise to prevent it from falling out.
| *a | Starter Body |
| *b | Terminal 50 |
| *c | Terminal 30 |
| *d | Ammeter |
Connect the battery and an ammeter to the starter assembly as shown in the illustration.
Do not allow any lead to get caught as the pinion gear operates.
Check that the starter operates smoothly and steadily with the pinion gear moving outward.
Measure the current according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Battery positive terminal - Terminal 30 - Terminal 50 | 11.5 V | 90 A or less |
If the result is not as specified, repair or replace the starter assembly.
28160
2.INSPECT STARTER ARMATURE ASSEMBLY
Check the commutator for an open circuit.
| *a | Segment |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Segment - Segment | Always | Below 1 Ω |
If the result is not as specified, replace the starter armature assembly.
Check the commutator for a short circuit.
| *a | Segment |
| *b | Starter Armature Core |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Segment - Starter Armature Core | Always | 10 kΩ or higher |
If the result is not as specified, replace the starter armature assembly.
Check the commutator appearance.
If the surface is dirty or burnt, restore it with sandpaper (No. 400) or on a lathe.
Check the commutator for runout.
Place the commutator on V-blocks.
Using a dial indicator, measure the runout.
0.05 mm (0.00197 in.)
If the runout is greater than the maximum, replace the starter armature assembly.
| *a | Diameter |
Using a vernier caliper, measure the commutator diameter.
28.0 mm (1.102 in.)
27.0 mm (1.063 in.)
If the diameter is less than the minimum, replace the starter armature assembly.
| *a | Undercut Depth |
Check that the undercut portion between the segments is free of foreign matter and measure its depth.
0.6 mm (0.0236 in.)
0.2 mm (0.00787 in.)
If the undercut depth is less than the minimum, adjust it with a hacksaw blade.
28120
3.INSPECT STARTER YOKE ASSEMBLY
Check the field coil for an open circuit.
| *a | Field Coil Brush Lead |
| *b | Lead Wire |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Lead Wire - Field Coil Brush Lead | Always | Below 1 Ω |
If the result is not as specified, replace the starter yoke assembly.
Check the field coil for a short circuit.
| *a | Field Coil Brush Lead |
| *b | Starter Yoke Body |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Field Coil Brush Lead - Starter Yoke Body | Always | 10 kΩ or higher |
If the result is not as specified, replace the starter yoke assembly.
4.INSPECT BRUSH
Using a vernier caliper, measure the brush length.
14 mm (0.551 in.)
9 mm (0.354 in.)
If the length is less than the minimum, replace the starter brush holder assembly and starter yoke assembly.
28140
5.INSPECT STARTER BRUSH HOLDER ASSEMBLY
Check the starter brush holder for a short circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Positive (+) Brush Holder - Negative (-) Brush Holder | Always | 10 kΩ or higher |
If the result is not as specified, replace the starter brush holder assembly.
28021
6.INSPECT STARTER CENTER BEARING CLUTCH SUB-ASSEMBLY
Check the starter center bearing clutch sub-assembly.
| *a | Free |
| *b | Lock |
While holding the starter center bearing clutch sub-assembly, rotate the pinion gear clockwise, and check that it turns freely. Try to rotate the pinion gear counterclockwise and check that it locks.
If the operation is not as specified, replace the starter center bearing clutch sub-assembly.
28150
7.INSPECT MAGNET STARTER SWITCH ASSEMBLY
Check the plunger.
Push in the plunger and check that it returns quickly to its original position.
To avoid damaging the inside of the magnet starter switch assembly, do not release the plunger quickly.
If the operation is not as specified, replace the magnet starter switch assembly.
| *a | Terminal 50 |
| *b | Terminal C |
Check the pull-in coil for an open circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminal 50 - Terminal C | Always | Below 1 Ω |
If the result is not as specified, replace the magnet starter switch assembly.
| *a | Terminal 50 |
| *b | Magnet Starter Switch Body |
Check the holding coil for an open circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminal 50 - Magnet Starter Switch Body | Always | Below 2 Ω |
If the result is not as specified, replace the magnet starter switch assembly.