Home › Engine / Hybrid System › 1NZ-FE EMISSION CONTROL › PCV VALVE › 2013.08–2016.10
RM30M0E _51 Engine / Hybrid System _017077 1NZ-FE EMISSION CONTROL _0090220 PCV VALVE A

1NZ-FE EMISSION CONTROL  PCV VALVE  INSTALLATION  


PROCEDURE

Hide 12204 1.INSTALL PCV VALVE (VENTILATION VALVE SUB-ASSEMBLY)

a.

Clean and degrease the threads of the PCV valve (ventilation valve sub-assembly) and threaded hole of the cylinder head cover sub-assembly.


b.
A302814C03
1.76,0.427 2.073,0.76 false 1.552,0.302 1.865,0.458 0.313,0.156 10 false *a
*a Adhesive


Apply adhesive to 2 or 3 threads of the PCV valve (ventilation valve sub-assembly).

Adhesive:

Toyota Genuine Adhesive 1324, Three Bond 1324 or equivalent


NOTICE:

To prevent contamination by foreign matter, install immediately after applying adhesive.



c.

Using a 19 mm deep socket wrench, install the PCV valve (ventilation valve sub-assembly) to the cylinder head cover sub-assembly.

Torque:
27 N*m (275 kgf*cm, 20 ft.*lbf)

NOTICE:

Do not start the engine for at least 1 hour after installation.



Hide 12261 2.CONNECT VENTILATION HOSE

a.

Connect the ventilation hose to the PCV valve (ventilation valve sub-assembly) with the hose clip.