Home › Drivetrain › U340E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM › 2013.08–2016.10
RM30M0E _52 Drivetrain _017087 U340E AUTOMATIC TRANSMISSION / TRANSAXLE _0090604 AUTOMATIC TRANSAXLE SYSTEM C

U340E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P0712  Transmission Fluid Temperature Sensor "A" Circuit Low Input  P0713  Transmission Fluid Temperature Sensor "A" Circuit High Input  


DESCRIPTION

The ATF (Automatic Transmission Fluid) temperature sensor converts the fluid temperature into a resistance value which is input to the ECM.

The sensor resistance changes with the transmission fluid temperature. As the temperature rises, the sensor resistance decreases. The ECM applies a voltage to the temperature sensor through ECM terminal THO1, and the ECM calculates the fluid temperature based on the voltage signal.

HINT:
·

The ATF temperature is likely to increase under conditions such as towing, climbing hills and in heavy traffic.

·

When the ATF temperature sensor is normal, the transmission locks up in 4th gear with the shift lever in D and in 3rd gear with the shift lever in 3rd.



DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input ATF temperature sensor resistance is less than 79 Ω for 0.5 seconds or more (1 trip detection logic).
·

Wire harness or connector

·

ATF temperature sensor (Transmission wire)

·

ECM


Comes on DTC stored
P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input Following condition continues for 0.5 seconds or more (1 trip detection logic).
ATF temperature sensor resistance is more than 156 kΩ after 15 minutes or more after starting engine.
·

Wire harness or connector

·

ATF temperature sensor (Transmission wire)

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature and detects opens or shorts in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79 Ω*1 or more than 156 kΩ*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM turns on the MIL and stores the DTC.

*1: 150°C (302°F) or more is indicated regardless of the actual ATF temperature.

*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:

The ATF temperature can be checked on the GTS display.


WIRING DIAGRAM

C243250E08
0.958,2.167 1.24,2.323 0.281,0.156 10 B20 0.958,2.333 2.146,2.479 1.188,0.146 10 Transmission Wire 1.208,0.885 2.313,1.208 1.104,0.323 10 ATF Temperature Sensor 2.427,0.802 2.75,0.958 0.323,0.156 10 THO 2.781,0.615 2.896,0.781 0.115,0.167 10 1 2.552,1.844 2.74,2 0.188,0.156 10 E2 2.781,1.656 2.896,1.813 0.115,0.156 10 6 5.375,0.719 5.677,0.938 0.302,0.219 10 B31 5.427,0.552 5.604,0.698 0.177,0.146 10 24 5.698,0.719 6.115,0.917 0.417,0.198 10 THO1 5.375,1.75 5.656,1.927 0.281,0.177 10 B31 5.427,1.573 5.604,1.719 0.177,0.146 10 32 5.698,1.75 6.146,1.969 0.448,0.219 10 ETHO 5.927,2.167 6.292,2.417 0.365,0.25 10 ECM

CAUTION / NOTICE / HINT

HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / Engine and ECT / Data List.

Powertrain > Engine and ECT > Data List
Tester Display
A/T Oil Temperature 1
50003 234 406

g.

In accordance with the display on the GTS, read the Data List.

Powertrain > Engine and ECT > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
A/T Oil Temperature 1 ATF temperature sensor value Min.: -40°C (-40°F)
Max.: 215°C (419°F)
·

Approximately 80°C (176°F): After Stall Test

·

Equal to ambient temperature while engine is cold


If the value is "-40°C (-40°F)" or "150°C (302°F) or more ", ATF temperature sensor circuit is opened or shorted.
HINT:

When DTC P0712 is output and the GTS reading is 150°C (302°F) or more, there is a short circuit.

When DTC P0713 is output and the GTS reading is -40°C (-40°F), there is an open circuit.

Measure the resistance between terminal THO1 and body ground.

Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
150°C (302°F) or more Short circuit


HINT:

If a circuit related to the ATF (Automatic Transmission Fluid) temperature sensor becomes open, P0713 is immediately set (within 0.5 seconds).




PROCEDURE

1.INSPECT ATF TEMPERATURE SENSOR (TRANSMISSION WIRE)
a.
C229166C32
2.302,0.948 2.677,0.771 true 2.292,1.271 2.677,1.625 true 2.719,0.688 3.115,0.844 0.396,0.156 10 false THO 2.719,1.531 2.948,1.688 0.229,0.156 10 false E2 0.063,0.031 0.26,0.198 0.198,0.167 10 false *a
*a Component without harness connected
(Transmission Wire)


Disconnect the B20 transmission wire connector from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (THO) - 6 (E2) Always 79 Ω to 156 kΩ
1 (THO) - Body ground Always 10 kΩ or higher
6 (E2) - Body ground Always


HINT:

If the resistance is outside the specified range at either of the ATF temperatures shown in the table below, the driveability of the vehicle may be affected.


ATF Temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ


Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

REPLACE ATF TEMPERATURE SENSOR (TRANSMISSION WIRE)

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
C279778C37
1.073,0.5 1.5,0.75 0.427,0.25 0.656,2.188 1.25,2.063 true 1.958,2.656 1.26,2.125 true 1.156,0.552 1.615,0.75 0.458,0.198 10 false B31 2.01,2.583 2.625,2.781 0.615,0.198 10 false ETHO 0.25,2.104 0.865,2.302 0.615,0.198 10 false THO1 0.135,0.104 0.448,0.302 0.313,0.198 10 false *a
*a Rear view of wire harness connector
(to ECM)


Connect the B20 transmission wire connector to the transaxle.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B31-24 (THO1) - B31-32 (ETHO) Always 79 Ω to 156 kΩ
B31-24 (THO1) - Body ground Always 10 kΩ or higher
B31-32 (ETHO) - Body ground Always



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR