The shift solenoid valve ST is switched OFF-ON-OFF in accordance with signals from the ECM when up-shifting and down-shifting between the 3rd and the 4th gears. This reduces the shock of gear shifting between these positions.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0787 | Shift / Timing Solenoid Low (Shift Solenoid Valve ST) | ECM detects short in solenoid valve ST circuit 4 times when solenoid valve ST is operated (1-trip detection logic). | ·
Wire harness or connector ·
Transmission wire ·
Shift solenoid valve ST ·
ECM |
Comes on | DTC stored |
| P0788 | Shift / Timing Solenoid High (Shift Solenoid Valve ST) | ECM detects open in solenoid valve ST circuit 4 times when solenoid valve ST is not operated (1-trip detection logic). | ·
Wire harness or connector ·
Transmission wire ·
Shift solenoid valve ST ·
ECM |
Comes on | DTC stored |
When there is an open or short circuit in the shift solenoid valve circuit, the ECM detects the problem and the MIL comes on.
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the B20 transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (ST) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to ECM) |
Connect the B20 transmission wire connector to the transaxle.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B31-8 (ST) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Shift Solenoid Valve ST) |
Remove the shift solenoid valve ST.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Solenoid Connector (ST) - Solenoid Body (ST) | 20°C (68°F) | 11 to 15 Ω |
Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.
The solenoid makes operating sounds.
| Proceed to |
|---|
| OK |
| NG |
OK
NG