Home › Drivetrain › U340E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM › 2013.08–2016.10
RM30M0E _52 Drivetrain _017087 U340E AUTOMATIC TRANSMISSION / TRANSAXLE _0090604 AUTOMATIC TRANSAXLE SYSTEM C

U340E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2769  Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)  P2770  Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)  


DESCRIPTION

The shift solenoid valve SL is turned ON and OFF by signals from the ECM to control the hydraulic pressure in the lock-up relay valve, which then controls the operation of the lock-up clutch.

Fail-safe function:

·

If the ECM detects a malfunction, it turns shift solenoid valve SL OFF.

·

The system cannot control the lock-up relay valve. (No relation to 3-4 shift control)


DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) ECM detects short in solenoid valve SL circuit when solenoid valve SL operated (2-trip detection logic).
·

Wire harness or connector

·

Transmission wire

·

Shift solenoid valve SL

·

ECM


Comes on DTC stored
P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) ECM detects open in solenoid valve SL circuit when solenoid valve SL not operated (Solenoid resistance: 100 kΩ or more) (2-trip detection logic).
·

Wire harness or connector

·

Transmission wire

·

Shift solenoid valve SL

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

Based on the signals from the throttle position sensor, the mass air flow meter and the crankshaft position sensor, the ECM sends a signal to shift solenoid valve SL to regulate the hydraulic pressure and provide smoother gear shifting. Shift solenoid valve SL responds to the signals from the ECM. The valve controls the lock-up relay valve to perform the torque converter lock-up function. If the ECM detects an open or short circuit of shift solenoid valve SL, it illuminates the MIL and sets a DTC.

WIRING DIAGRAM

C243326E32
0.979,1.958 1.292,2.125 0.313,0.167 10 false B20 0.979,2.115 2.167,2.292 1.188,0.177 10 false Transmission Wire 6.021,2.177 6.375,2.344 0.354,0.167 10 false ECM 5.833,1.094 6.031,1.25 0.198,0.156 10 false SL 5.448,1.104 5.729,1.271 0.281,0.167 10 false B31 5.479,0.906 5.656,1.063 0.177,0.156 10 false 11 2.302,1.219 2.5,1.375 0.198,0.156 10 false SL 2.615,0.99 2.708,1.146 0.094,0.156 10 false 4 1.146,1.344 2.042,1.656 0.896,0.313 10 false Shift Solenoid Valve SL

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
a.
C229166C37
1.375,0.938 1,0.563 true 0.75,0.479 0.969,0.635 0.219,0.156 10 false SL 0.063,0.031 0.26,0.198 0.198,0.167 10 false *a
*a Component without harness connected
(Transmission Wire)


Disconnect the B20 transmission wire connector from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (SL) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SL
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
C279778C43
1.073,0.583 1.5,0.833 0.427,0.25 2.083,2.583 1.385,2 true 1.167,0.635 1.625,0.833 0.458,0.198 10 false B31 2.135,2.5 2.75,2.698 0.615,0.198 10 false SL 0.135,0.156 0.448,0.365 0.313,0.208 10 false *a
*a Rear view of wire harness connector
(to ECM)


Connect the B20 transmission wire connector to the transaxle.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B31-11 (SL) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SL
a.
C117935C05
0.104,0.098 1.965,0.287 1.862,0.189 10 *a 0.398,3.021 0.589,3.202 0.191,0.182 10 (+) 0.421,3.623 0.577,3.804 0.156,0.182 10 (-)
*a Component without harness connected
(Shift Solenoid Valve SL)


Remove the shift solenoid valve SL.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (SL) - Solenoid Body (SL) 20°C (68°F) 11 to 15 Ω



c.

Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.

OK:

The solenoid makes operating sounds.



Result:
Proceed to
OK
NG



OK

NG