The shift solenoid valve SL is turned ON and OFF by signals from the ECM to control the hydraulic pressure in the lock-up relay valve, which then controls the operation of the lock-up clutch.
Fail-safe function:
If the ECM detects a malfunction, it turns shift solenoid valve SL OFF.
The system cannot control the lock-up relay valve. (No relation to 3-4 shift control)
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2769 | Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) | ECM detects short in solenoid valve SL circuit when solenoid valve SL operated (2-trip detection logic). | ·
Wire harness or connector ·
Transmission wire ·
Shift solenoid valve SL ·
ECM |
Comes on | DTC stored |
| P2770 | Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL) | ECM detects open in solenoid valve SL circuit when solenoid valve SL not operated (Solenoid resistance: 100 kΩ or more) (2-trip detection logic). | ·
Wire harness or connector ·
Transmission wire ·
Shift solenoid valve SL ·
ECM |
Comes on | DTC stored |
Based on the signals from the throttle position sensor, the mass air flow meter and the crankshaft position sensor, the ECM sends a signal to shift solenoid valve SL to regulate the hydraulic pressure and provide smoother gear shifting. Shift solenoid valve SL responds to the signals from the ECM. The valve controls the lock-up relay valve to perform the torque converter lock-up function. If the ECM detects an open or short circuit of shift solenoid valve SL, it illuminates the MIL and sets a DTC.
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the B20 transmission wire connector from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (SL) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to ECM) |
Connect the B20 transmission wire connector to the transaxle.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B31-11 (SL) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Shift Solenoid Valve SL) |
Remove the shift solenoid valve SL.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Solenoid Connector (SL) - Solenoid Body (SL) | 20°C (68°F) | 11 to 15 Ω |
Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.
The solenoid makes operating sounds.
| Proceed to |
|---|
| OK |
| NG |
OK
NG