35240
1.INSPECT SHIFT SOLENOID VALVE S1
| *a | Component without harness connected
(Shift Solenoid Valve S1) |
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Solenoid Connector (S1) - Solenoid Body (S1) | 20°C (68°F) | 11 to 15 Ω |
If the result is not as specified, replace the shift solenoid valve S1.
Check the operation.
Connect the positive (+) lead from the battery to the terminal of the solenoid connector and the negative (-) lead to the solenoid body, then check the operation of the solenoid valve.
The solenoid valve makes an operating sound.
If the operation cannot be done as specified, replace the shift solenoid valve S1.
While using the battery during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
35230
2.INSPECT SHIFT SOLENOID VALVE S2
Refer to Inspect Shift Solenoid Valve S1.
35270A
3.INSPECT SHIFT SOLENOID VALVE SL
Refer to Inspect Shift Solenoid Valve S1.
35250A
4.INSPECT SHIFT SOLENOID VALVE ST
Refer to Inspect Shift Solenoid Valve S1.
35290A
5.INSPECT SHIFT SOLENOID VALVE SLT
Check the resistance.
| *a | Component without harness connected
(Shift Solenoid Valve SLT) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
If the result is not as specified, replace the shift solenoid valve SLT.
Check the operation.
Connect the positive (+) lead with a 21 W bulb from the battery to terminal 2 and the negative (-) lead to terminal 1, then check the operation of the solenoid valve.
The solenoid valve makes an operating sound.
If the operation cannot be done as specified, replace the shift solenoid valve SLT.
While using the battery during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.