Home › Drivetrain › U441E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM › 2013.08–2016.10
RM30M0E _52 Drivetrain _017088 U441E AUTOMATIC TRANSMISSION / TRANSAXLE _0090618 AUTOMATIC TRANSAXLE SYSTEM C

U441E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P0976  Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2)  P0977  Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2)  


DESCRIPTION

Shifting from 1st to 4th is performed in combination with the ON and OFF operations of shift solenoid valves S1 and S2 which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be driven smoothly.

(If an open or short circuit occurs, the ECM stops sending current to the affected circuit.)

Fail-safe function.

Click hereDrivetrain>U441E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0976 Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2) ECM detects short in solenoid valve S2 circuit 4 times when solenoid valve S2 is operated (1 trip detection logic).
·

Wire harness or connector

·

Transmission wire

·

Shift solenoid valve S2

·

ECM


Comes on DTC stored
P0977 Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2) ECM detects open in solenoid valve S2 circuit 4 times when solenoid valve S2 is not operated (1 trip detection logic).
·

Wire harness or connector

·

Transmission wire

·

Shift solenoid valve S2

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

The ECM commands gear shifts by turning the shift solenoid valves ON/OFF. When there is an open or short circuit in the shift solenoid valve S2 circuit, the ECM detects the problem and the MIL comes on. Illuminating the MIL, the ECM performs the fail-safe and turns the other functioning shift solenoid valve ON/OFF.

(If an open or short circuit occurs, the ECM stops sending current to the affected circuit.)

WIRING DIAGRAM

C243326E27
0.979,1.958 1.292,2.125 0.313,0.167 10 B20 0.979,2.115 2.167,2.292 1.188,0.177 10 Transmission Wire 6.021,2.177 6.375,2.344 0.354,0.167 10 ECM 5.833,1.094 6.031,1.25 0.198,0.156 10 S2 5.458,1.094 5.771,1.313 0.313,0.219 10 B31 5.51,0.896 5.688,1.052 0.177,0.156 10 9 2.292,1.219 2.49,1.375 0.198,0.156 10 S2 2.615,0.99 2.813,1.167 0.198,0.177 10 10 1.146,1.333 2.042,1.646 0.896,0.313 10 Shift Solenoid Valve S2

CAUTION / NOTICE / HINT

HINT:

The shift solenoid valve S2 is turned on/off normally when the shift lever is in D:


Gearshift controlled by ECM 1st 2nd 3rd 4th
Shift solenoid valve S2 ON OFF OFF ON

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2)
a.
C229166C29
1.104,1.302 0.646,1.583 true 0.375,1.521 0.573,1.677 0.198,0.156 10 false S2 0.063,0.031 0.26,0.198 0.198,0.167 10 false *a
*a Component without harness connected
(Transmission Wire)


Disconnect the B20 transmission wire connector from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
10 (S2) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE S2
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
C279778C34
1,0.5 1.417,0.75 0.417,0.25 2.104,2.594 1.479,2 true 1.094,0.542 1.552,0.74 0.458,0.198 10 false B31 2.156,2.51 2.771,2.708 0.615,0.198 10 false S2 0.115,0.073 0.427,0.271 0.313,0.198 10 false *a
*a Rear view of wire harness connector
(to ECM)


Connect the B20 transmission wire connector to the transaxle.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B31-9 (S2) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE S2
a.
C117936C06
0.698,2.854 0.896,3.052 0.198,0.198 10 false (-) 0.073,0.021 1.677,0.208 1.604,0.188 10 false *a 1.323,2.865 1.521,3.063 0.198,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve S2)


Remove the shift solenoid valve S2.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (S2) - Solenoid Body (S2) 20°C (68°F) 11 to 15 Ω



c.

Connect the positive (+) lead to the terminal of the solenoid connector and the negative (-) lead to the solenoid body to check the solenoid valve operation.

OK:

The solenoid makes operating sounds.



Result:
Proceed to
OK
NG



OK

NG