Home › Drivetrain › U441E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM › 2013.08–2016.10
RM30M0E _52 Drivetrain _017088 U441E AUTOMATIC TRANSMISSION / TRANSAXLE _0090618 AUTOMATIC TRANSAXLE SYSTEM C

U441E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2716  Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)  


DESCRIPTION

The shift solenoid valve SLT controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and vehicle speed sensor. The ECM adjusts the shift solenoid valve SLT to control hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.

C279814E03
4.729,1.167 5.042,0.646 true 4.927,0.198 5.208,0.5 true 5.25,1.5 5.917,1.5 5.917,1.5 6.146,0.927 true 5.667,1.5 6.167,0.417 true 0.688,0.656 1.781,1.031 1.094,0.375 10 false Line Pressure Control Pressure 1.729,1.563 3.365,1.74 1.635,0.177 10 false Current Flow to Solenoid 3.958,1.094 4.719,1.271 0.76,0.177 10 false Spool Valve 4.479,0.104 4.948,0.281 0.469,0.177 10 false Sleeve 4.375,1.417 5.302,1.583 0.927,0.167 10 false Solenoid Coil

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detecting logic).
·

Wire harness or connector

·

Transmission wire

·

Shift solenoid valve SLT

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM turn on the MIL and stores the DTC.

WIRING DIAGRAM

C243327E08
1.083,2.146 1.365,2.323 0.281,0.177 10 false B20 1.094,2.313 2.281,2.49 1.188,0.177 10 false Transmission Wire 2.271,0.771 2.656,0.927 0.385,0.156 10 false SLT+ 2.75,0.542 2.885,0.719 0.135,0.177 10 false 3 2.281,1.729 2.635,1.885 0.354,0.156 10 false SLT- 2.75,1.49 2.885,1.667 0.135,0.177 10 false 8 5.49,0.51 5.667,0.677 0.177,0.167 10 false 12 5.458,0.688 5.771,0.844 0.313,0.156 10 false B31 5.479,1.479 5.656,1.646 0.177,0.167 10 false 13 5.458,1.646 5.771,1.802 0.313,0.156 10 false B31 5.833,0.656 6.24,0.813 0.406,0.156 10 false SLT+ 5.833,1.625 6.24,1.781 0.406,0.156 10 false SLT- 6.104,2.115 6.458,2.292 0.354,0.177 10 false ECM 1.271,0.938 2.146,1.25 0.875,0.313 10 false Shift Solenoid Valve SLT

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
a.
C229166C30
1.76,0.917 2.094,0.51 true 1.771,1.281 2,1.771 true 2.135,0.417 2.531,0.573 0.396,0.156 10 false SLT+ 2.083,1.708 2.479,1.865 0.396,0.156 10 false SLT- 0.063,0.031 0.26,0.198 0.198,0.167 10 false *a
*a Component without harness connected
(Transmission Wire)


Disconnect the B20 transmission wire connector from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 (SLT+) - 8 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
3 (SLT+) - Body ground Always 10 kΩ or higher
8 (SLT-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLT
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
C279778C35
1.073,0.583 1.5,0.833 0.427,0.25 1.99,2.583 1.344,2.01 true 0.844,2.563 1.302,2.01 true 1.167,0.635 1.625,0.833 0.458,0.198 10 false B31 0.51,2.49 0.896,2.677 0.385,0.188 10 false SLT- 2.042,2.5 2.656,2.698 0.615,0.198 10 false SLT+ 0.104,0.135 0.417,0.333 0.313,0.198 10 false *a
*a Rear view of wire harness connector
(to ECM)


Connect the B20 transmission wire connector to the transaxle.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B31-12 (SLT+) - B31-13 (SLT-) 20°C (68°F) 5.1 to 5.5 Ω
B31-12 (SLT+) - Body ground Always 10 kΩ or higher
B31-13 (SLT-) - Body ground Always



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SLT
a.
C279806C03
1.469,0.948 0.896,0.771 true 1.438,3.063 0.865,2.885 true 2.323,0.823 1.74,0.958 true 2.292,2.76 1.74,3.073 true 0.104,0.094 0.417,0.292 0.313,0.198 10 false *a 0.75,0.688 1.063,0.885 0.313,0.198 10 false 1 2.385,0.75 2.698,0.948 0.313,0.198 10 false 2 0.75,2.792 1.063,2.99 0.313,0.198 10 false 1 2.385,2.635 2.698,2.833 0.313,0.198 10 false 2 2.854,3.427 3.208,3.656 0.354,0.229 10 false 21W 1.156,4.052 1.469,4.25 0.313,0.198 10 false (-) 1.896,4.052 2.208,4.25 0.313,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve SLT)


Remove the shift solenoid valve SLT.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.1 to 5.5 Ω



c.

Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

OK:

The solenoid makes operating sounds.



Result:
Proceed to
OK
NG



OK

NG