Home › Drivetrain › U441E AUTOMATIC TRANSMISSION / TRANSAXLE › VALVE BODY ASSEMBLY › 2013.08–2016.10
RM30M0E _52 Drivetrain _017088 U441E AUTOMATIC TRANSMISSION / TRANSAXLE _0090622 VALVE BODY ASSEMBLY G

U441E AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35250C 1.INSPECT SHIFT SOLENOID VALVE S1

C117936C01
0.698,2.854 0.896,3.052 0.198,0.198 10 false (-) 0.073,0.021 1.677,0.208 1.604,0.188 10 false *a 1.323,2.865 1.521,3.063 0.198,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve S1)


a.

Check the resistance.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (S1) - Solenoid Body (S1) 20°C (68°F) 11 to 15 Ω


If the result is not as specified, replace the shift solenoid valve S1.



b.

Check the operation.

i.

Connect the positive (+) lead from the battery to the terminal of the solenoid connector and the negative (-) lead to the solenoid body, then check the operation of the solenoid valve.

OK:

The solenoid valve makes an operating sound.


If the operation cannot be done as specified, replace the shift solenoid valve S1.

NOTICE:

While using the battery during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.




Hide 2.INSPECT SHIFT SOLENOID VALVE S2

HINT:

Refer to Inspect Shift Solenoid Valve S1.


Hide 35250A 3.INSPECT SHIFT SOLENOID VALVE SL

HINT:

Refer to Inspect Shift Solenoid Valve S1.


Hide 35250D 4.INSPECT SHIFT SOLENOID VALVE ST

HINT:

Refer to Inspect Shift Solenoid Valve S1.


Hide 35290 5.INSPECT SHIFT SOLENOID VALVE SLT

a.

Check the resistance.

i.
C279806C01
1.469,0.948 0.896,0.771 true 1.438,3.063 0.865,2.885 true 2.323,0.823 1.74,0.958 true 2.292,2.76 1.74,3.073 true 0.104,0.094 0.417,0.292 0.313,0.198 10 false *a 0.75,0.688 1.063,0.885 0.313,0.198 10 false 1 2.385,0.75 2.698,0.948 0.313,0.198 10 false 2 0.75,2.792 1.063,2.99 0.313,0.198 10 false 1 2.385,2.635 2.698,2.833 0.313,0.198 10 false 2 2.854,3.427 3.208,3.656 0.354,0.229 10 false 21W 1.156,4.052 1.469,4.25 0.313,0.198 10 false (-) 1.896,4.052 2.208,4.25 0.313,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve SLT)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.1 to 5.5 Ω


If the result is not as specified, replace the shift solenoid valve SLT.



b.

Check the operation.

i.

Connect the positive (+) lead with a 21 W bulb from the battery to terminal 2 and the negative (-) lead to terminal 1, then check the operation of the solenoid valve.

OK:

The solenoid valve makes an operating sound.


If the operation cannot be done as specified, replace the shift solenoid valve SLT.

NOTICE:

While using the battery during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.