Home › Drivetrain › C50 MANUAL TRANSMISSION / TRANSAXLE › SHIFT LEVER ASSEMBLY › 2013.08–2014.03
RM30M0E _52 Drivetrain _017090 C50 MANUAL TRANSMISSION / TRANSAXLE _0091169 SHIFT LEVER ASSEMBLY A

C50 MANUAL TRANSMISSION / TRANSAXLE  SHIFT LEVER ASSEMBLY  INSTALLATION  


PROCEDURE

Hide 33530F 1.INSTALL FLOOR SHIFT SHIFT LEVER ASSEMBLY

a.

Install the floor shift shift lever assembly to the body with the 4 bolts.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)


b.

Engage the 2 clamps and install the wire harness to the floor shift shift lever assembly.


Hide 33820B 2.CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY

a.
C288539C01
2.24,0.906 2.552,0.708 false 1,1.875 1.313,1.677 false 0.854,1.781 1.167,1.938 0.313,0.156 10 false *1 2.594,0.604 2.906,0.76 0.313,0.156 10 false *2
*1 Nut
*2 Lock
V100135

Rotate approximately 180°
V100136

Push in


Rotate the 2 nuts of the transmission control cable assembly approximately 180° in the direction shown in the illustration, and while holding the nut, push in the lock.

NOTICE:

Do not rotate the nut excessively as it may damage the internal spring and the transmission control cable assembly will not be reusable.



b.
C283111C02
1.281,3.729 0.938,3.542 false 0.813,0.615 0.531,0.417 false 2.646,0.604 2.365,0.406 false 2.156,3.604 2,3.719 false 2.854,3.396 2.698,2.771 true 2.167,3.5 2.396,3.698 0.229,0.198 10 false *1 2.813,3.417 3.01,3.583 0.198,0.167 10 false *2 0.375,0.323 0.688,0.479 0.313,0.156 10 false *a 2.219,0.323 2.531,0.479 0.313,0.156 10 false *3 0.313,0.573 0.469,0.771 0.156,0.198 10 false A 1.25,0.573 1.406,0.771 0.156,0.198 10 false A 0.792,3.448 1.104,3.604 0.313,0.156 10 false *a
*1 Clip A
*2 Clip B
*3 Lock
*a Protrusion


Install the transmission control cable assembly to the floor shift shift lever assembly.

NOTICE:
·

Install the transmission control cable assembly with the protrusion of the cable outer facing upwards.

·

After installation, make sure that the lock is projecting from A as shown in the illustration.




c.

Engage the clip B and connect the shift cable end of the transmission control cable assembly to the floor shift shift lever assembly.


d.

Connect the select cable end of the transmission control cable assembly to the floor shift shift lever assembly with the clip A.

NOTICE:
·

Install the transmission control cable assembly with the protrusion of the select cable end facing upwards.

·

Perform the installation with the clip A at the correct direction as shown in the illustration.