22204
1.INSPECT MASS AIR FLOW METER
Check the visual appearance
| *a | Platinum Hot Wire (Heater) |
Perform a visual check for any foreign matter on the platinum hot wire (heater) of the mass air flow meter shown in the illustration.
There is no foreign matter.
If the result is not as specified, replace the mass air flow meter.
Check the resistance
| *a | Component without harness connected
(Mass Air Flow Meter) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (THA) - 2 (E2) | -20°C (-4°F) | 13.6 to 18.4 kΩ |
| 20°C (68°F) | 2.21 to 2.69 kΩ | |
| 60°C (140°F) | 0.49 to 0.67 kΩ |
If the resistance is not as specified, replace the mass air flow meter.