RM30M0E
_V1
General
_017290
SPECIFICATIONS
_0096999
2NZ-FE COOLING
F
SPECIFICATIONS 2NZ-FE COOLING SERVICE DATA
| Thermostat
|
Valve opening temperature
|
80 to 84°C (176 to 183°F)
|
| Valve lift
|
8.5 mm (0.335 in.) or more at 95°C (203°F)
|
| Cooling fan motor
|
Standard current
|
Positive (+) battery terminal - 2
|
12.4 to 15.4 A (at 12 V) 20°C (68°F)
|
| Cooling fan resistor
|
Standard resistance
|
1 - 2
|
1.17 to 1.43 Ω at 20°C (68°F)
|
| Fan No. 1 Relay
|
Standard resistance
|
3 - 5
|
Below 1 Ω (Battery voltage applied to terminals 1 and 2)
|
| 10 kΩ or higher (Battery voltage not applied)
|
| Fan No. 2 Relay
|
Standard resistance
|
3 - 4
|
Below 1 Ω (Battery voltage not applied to terminals 1 and 2)
|
| 10 kΩ or higher (Battery voltage applied to terminals 1 and 2)
|
| 3 - 5
|
10 kΩ or higher (Battery voltage not applied to terminals 1 and 2)
|
| Below 1 Ω (Battery voltage applied to terminals 1 and 2)
|
| Radiator cap sub-assembly
|
Standard valve (for brand-new cap)
|
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
|
| Minimum standard valve (for after using cap)
|
78.5 kPa (0.80 kgf/cm2, 11.4 psi)
|
COOLANT
| Capacity
|
Classification
|
with Fan shroud ventilation duct: 5.0 liters (5.3 US qts, 4.4 Imp. qts)
without Fan shroud ventilation duct: 4.6 liters (4.9 US qts, 4.0 Imp. qts)
|
Use only "TOYOTA Super Long Life Coolant", or similar high qualityethylene glycol based non-silicate, non-amine, non-nitrite, and nonboratecoolant with long-life hybrid organic acid technology (coolantwith long-life hybrid organic acid technology is a combination of lowphosphates and organic acids).
|