Use the same procedure for both the LH and RH side.
The procedure described below is for the LH side.
75561
1.INSTALL NO. 1 ROOF DRIP SIDE FINISH MOULDING CLIP
When installing new No. 1 roof drip side finish moulding clips, remove the double-sided tape remaining where the No. 1 roof drip side finish moulding clips will be installed on the vehicle body and clean the vehicle body with non-residue solvent.
| *a | Adhesive |
| *b | 2 to 3 mm bead of adhesive |
Apply a 2 to 3 mm (0.0787 to 0.118 in.) bead of adhesive to 2 new No. 1 roof drip side finish moulding clips.
Adhesive strength (tensile strength): 13.7 MPa (140.0 kgf/cm2, 1987 psi) or more (when the temperature is 23°C (73°F).)
Install the No. 1 roof drip side finish moulding clips to the positions on the roof panel shown in the illustration. Determine the locations and firmly press and install the 2 No. 1 roof drip side finish moulding clips after lightly applying adhesive.
| Dimension | Measurement |
|---|---|
| A | 3.1 mm (0.122 in.) |
| B | 1.2 to 2.2 mm (0.0473 to 0.0866 in.) |
| C | 4.0 mm (0.157 in.) |
| D | 3.5 mm (0.138 in.) |
| E | 4.7 mm (0.185 in.) |
| F | 1.0 to 2.0 mm (0.0394 to 0.0787 in.) |
Install the roof drip side finish moulding when 20 minutes or more have elapsed after pressing and installing the 2 No. 1 roof drip side finish moulding clips.
Initial hardening time: 20 minutes
Complete hardening time: 48 hours
75552E
2.INSTALL ROOF DRIP SIDE FINISH MOULDING
Engage the 2 clips and install the roof drip side finish moulding.
Remove the protective tape.