Home › Drivetrain › K411 CVT › CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM › from 2016.04
RM30M0E _52 Drivetrain _052750 K411 CVT _0254682 CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM D

K411 CVT  CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM  HYDRAULIC TEST  


PERFORM HYDRAULIC TEST


a.

Measure the secondary oil pressure.

CAUTION:

The secondary oil pressure test should always be carried out with at least 2 people. One person should observe the condition of the wheels and wheel chocks while the other is performing the test.


NOTICE:
·

This test must be conducted after checking and confirming that the engine is operating normally.

·

Perform this test while the CVT fluid temperature is between 50 and 100°C (122 and 212°F).

·

Perform this test with the A/C off.

·

Do not perform the stall speed test for more than 5 seconds.

·

When performing the stall speed test more than once, make sure to wait 15 seconds or more between tests.



i.

Fully apply the parking brake and chock all 4 wheels.


ii.

Connect the GTS to the DLC3.


iii.

Start the engine.


iv.

Turn the GTS on.


v.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Connect the TC and TE1.

HINT:

Observe the value of A/T Oil Pressure in the Data List on the screen while performing the Active Test.


Powertrain > Engine and ECT > Active Test
Tester Display
Connect the TC and TE1
50004 234 13

vi.

Keep your left foot firmly on the brake pedal and move the shift lever to D.


vii.

Depress the accelerator pedal as much as possible with your right foot. Quickly read the highest secondary oil pressure reading when the engine speed reaches stall speed and release the accelerator pedal immediately.


viii.

Keep your left foot firmly on the brake pedal and move the shift lever to R.


ix.

Depress the accelerator pedal as much as possible with your right foot. Quickly read the highest secondary oil pressure reading when the engine speed reaches stall speed and release the accelerator pedal immediately.

Specified Secondary Oil Pressure
Shift Lever Position Secondary Oil Pressure
D 4.4 to 6.5 MPa
(44.9 to 66.3 kgf/cm2, 638 to 943 psi)
R 4.4 to 6.8 MPa
(44.9 to 69.3 kgf/cm2, 638 to 986 psi)

HINT:

If the secondary oil pressure exceeds the maximum value or drops below the minimum value, a solenoid valve, regulator valve or modulator valve may be malfunctioning.