Home › Power Source / Network › 2NR-FE BATTERY / CHARGING › CHARGING SYSTEM › from 2016.04
RM30M0E _57 Power Source / Network _052956 2NR-FE BATTERY / CHARGING _0256535 CHARGING SYSTEM U

2NR-FE BATTERY / CHARGING  CHARGING SYSTEM  TERMINALS OF ECM  


CHECK ECM (for CVT)


A371911E08
0.667,0.583 1,0.75 0.333,0.167 2.083,0.583 2.417,0.75 0.333,0.167 3.5,0.583 3.833,0.75 0.333,0.167 4.833,0.583 5.167,0.75 0.333,0.167 6.083,0.583 6.417,0.75 0.333,0.167 0.719,0.583 1.177,0.781 0.458,0.198 10 false B46 2.135,0.583 2.594,0.781 0.458,0.198 10 false B47 3.552,0.583 4.01,0.781 0.458,0.198 10 false B48 4.844,0.583 5.302,0.781 0.458,0.198 10 false F130 6.094,0.583 6.552,0.781 0.458,0.198 10 false F131

HINT:

The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
B46-3 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
F131-3 (BATT) - B46-3 (E1) G - W-B Battery (for measuring battery voltage and for ECM memory) Always 10.5 to 16 V
B47-16 (LIN) - Body ground LG - Body ground LIN communication line Ignition switch off 10 kΩ or higher


CHECK ECM (for Manual Transaxle)


A301712E17
5.385,0.292 5.75,0.531 0.365,0.24 4.094,0.281 4.458,0.521 0.365,0.24 2.646,0.292 3.01,0.531 0.365,0.24 1.281,0.292 1.646,0.531 0.365,0.24 5.417,0.333 5.875,0.531 0.458,0.198 10 false F131 4.125,0.323 4.583,0.521 0.458,0.198 10 false F130 2.698,0.323 3.156,0.521 0.458,0.198 10 false B47 1.323,0.323 1.781,0.521 0.458,0.198 10 false B46

HINT:

The standard normal voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the ECM terminal locations.


Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
B46-3 (E1) - Body ground W-B - Body ground Ground Always Below 1 Ω
F131-3 (BATT) - B46-3 (E1) G - W-B Battery (for measuring battery voltage and for ECM memory) Always 10.5 to 16 V
B47-16 (LIN) - Body ground LG - Body ground LIN communication line Ignition switch off 10 kΩ or higher