Home › Power Source / Network › 2NR-FE BATTERY / CHARGING › CHARGING SYSTEM › from 2016.04
RM30M0E _57 Power Source / Network _052956 2NR-FE BATTERY / CHARGING _0256535 CHARGING SYSTEM U

2NR-FE BATTERY / CHARGING  CHARGING SYSTEM  DATA LIST / ACTIVE TEST  


DATA LIST


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under Normal Condition are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the A/C switch off.


c.

Turn the ignition switch off.


d.

Connect the GTS to the DLC3.


e.

Turn the ignition switch to ON.


f.

Turn the GTS on.


g.

Enter the following menus: Powertrain / Engine and ECT / Data List.


h.

According to the display on the GTS, read the Data List.

HINT:

Normal Condition: If no idling conditions are specified, the shift lever should be in N (Neutral) or P*1, and the A/C switch and all accessory switches should be off.

*1: for CVT



Powertrain > Engine and ECT > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Battery Voltage Battery voltage Min.: 0.0 V
Max.: 65.5 V
10.5 to 16 V: Idling If the result is not as specified, abnormal battery voltage is suspected.
Alternator Output Duty Generator output duty Min.: 0.0%
Max.: 399.9%
Changes according to alternator output If the result is not as specified, a malfunction of the charging system is suspected.
Alt Vol - Non Active Test Requested voltage when regulator forced drive is not executed Min.: 0.0 V
Max.: 79.998 V
10.5 to 16 V:
Varies with battery temperature or driving conditions: After engine start
If the result is not as specified, a malfunction of the charging system is suspected.
Alt Vol - Active Test Request voltage when regulator under forced activation Min.: 0 V
Max.: 79.998 V
10.6 to 16 V:
Request instruction voltage value: After engine start
If the result is not as specified, a malfunction of the charging system is suspected.


ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Active Test.


e.

According to the display on the GTS, perform the Active Test.

Powertrain > Engine and ECT > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Control the Voltage of Alternator Requested output voltage of generator regulator during forced activation Between 10.6 to 16 V Test is possible after engine start