89120A
1.INSPECT AUTOMATIC LIGHT CONTROL SENSOR
| *a | Front view of wire harness connector
(Automatic Light Control Sensor) |
Disconnect the automatic light control sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K1-1 (CLTB) - K1-2 (CLTE) | Ignition switch on (IG) | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K1-2 (CLTE) - Body ground | Always | Below 1 Ω |
| *a | Component with harness connected
(Automatic Light Control Sensor) |
Connect the automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
Check the waveform.
| Tester Connection | Tool Setting | Condition | Specified Condition |
|---|---|---|---|
| K1-4 (CLTS) - K1-2 (CLTE) | 2 V/DIV., 10 ms./DIV. | Ignition switch on (IG), light control switch in AUTO position | Correct waveform is as shown |
The communication waveform changes according to the surrounding brightness.
If the result is not as specified, replace the automatic light control sensor.
88625H
2.INSPECT COOLER (SOLAR SENSOR) THERMISTOR
Check the resistance.
| *a | Component without harness connected
(Cooler (Solar Sensor) Thermistor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (SS+) - 2 (SS-) | Without direct light exposure (Sensor covered) | ∞ Ω |
| 1 (SS+) - 2 (SS-) | When exposed to sunlight or an inspection light | Except ∞ Ω |
The connection procedure for using a digital tester such as an electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 2 (SS-) and the negative (-) lead to terminal 1 (SS+) of the cooler (solar sensor) thermistor.
As the inspection light is moved away from the cooler (solar sensor) thermistor, the voltage decreases.
Use an incandescent light for the inspection. Position it about 30 cm (11.8 in.) from the cooler (solar sensor) thermistor.
If the result is not as specified, replace the cooler (solar sensor) thermistor.