88719A
1.INSTALL AIR CONDITIONER PRESSURE SENSOR
Remove the vinyl tape from the No. 1 cooler refrigerant suction hose and the connecting part of the air conditioner pressure sensor.
Apply sufficient compressor oil to a new air conditioner pressure sensor and connecting surface.
ND-OIL 8 or equivalent
| *a | Turn |
| *b | Hold |
Using a 27 mm deep socket wrench, install the air conditioner pressure sensor.
Connect the connector.
2.CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
3.WARM UP ENGINE
4.INSPECT FOR REFRIGERANT LEAK