1.INSPECT AUTOMATIC LIGHT CONTROL SENSOR
| *a | Front view of wire harness connector
(Automatic Light Control Sensor) |
Disconnect the automatic light control sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K1-1 (CLTB) - K1-2 (CLTE) | Ignition switch on (IG) | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| K1-2 (CLTE) - Body ground | Always | Below 1 Ω |
| *a | Component with harness connected
(Automatic Light Control Sensor) |
Connect the automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
Check the waveform.
| Tester Connection | Tool Setting | Condition | Specified Condition |
|---|---|---|---|
| K1-4 (CLTS) - K1-2 (CLTE) | 2 V/DIV., 10 ms./DIV. | Ignition switch on (IG), light control switch in AUTO position | Correct waveform is as shown |
The communication waveform changes according to the surrounding brightness.
If the result is not as specified, replace the automatic light control sensor.