16321
1.INSPECT WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
Check the valve opening temperature of the water inlet with thermostat sub-assembly.
80 to 84°C (176 to 183°F)
If the valve opening temperature is not as specified, replace the water inlet with thermostat sub-assembly.
| *a | 8.5 mm or more |
Check the valve lift.
8.5 mm (0.335 in.) or more at 95°C (203°F)
If the result is not as specified, replace the water inlet with thermostat sub-assembly.
Check that the valve is fully closed when the water inlet with thermostat sub-assembly is at low temperatures (below 77°C (171°F)).
If it is not fully closed, replace the water inlet with thermostat sub-assembly.