Home › Engine / Hybrid System › 1NR-FE EMISSION CONTROL › PURGE VALVE › from 2016.04
RM30M0E _51 Engine / Hybrid System _053552 1NR-FE EMISSION CONTROL _0259976 PURGE VALVE G

1NR-FE EMISSION CONTROL  PURGE VALVE  INSPECTION  


PROCEDURE

Hide 25860 1.INSPECT PURGE VSV (PURGE VALVE)

a.

Check the resistance.

i.
A302932C01
0.104,0.104 0.417,0.302 0.313,0.198 10 false *a 1.813,1.094 2,1.333 0.188,0.24 14 false 1 1.479,1.094 1.667,1.333 0.188,0.24 14 false 2
*a Component without harness connected
(Purge VSV)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω


If the result is not as specified, replace the purge VSV.



b.

Check the operation.

i.
A382996C01
0.76,1.688 0.833,1.917 false 1.427,1.208 1.542,1.49 false 0.823,1.979 1.135,2.177 0.313,0.198 10 false *d 1.51,1.521 1.823,1.719 0.313,0.198 10 false *c 1.979,1.531 2.292,1.729 0.313,0.198 10 false *b 2.25,0.125 2.563,0.323 0.313,0.198 10 false *a
*a Component without harness connected
(Purge VSV)
*b Air
*c Port E
*d Port F


Apply battery voltage between the terminals of the purge VSV and check that the following occurs when blowing air into port E.

OK:
Condition Specified Condition
Battery positive → terminal 1
Battery negative → terminal 2
Air flows from port F.
Battery voltage not applied to terminals 1 and 2 Air does not flow.