22204
1.INSPECT MASS AIR FLOW METER
Check the visual appearance.
| *a | Platinum Hot Wire (Heater) and Platinum Cold Wire |
Perform a visual check for any foreign matter on the platinum hot wire (heater) and platinum cold wire of the mass air flow meter shown in the illustration.
There is no foreign matter.
If the result is not as specified, replace the mass air flow meter.
Check the resistance.
| *a | Component without harness connected
(Mass Air Flow Meter) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (THA) - 2 (E2) | -20°C (-4°F) | 13.6 to 18.4 kΩ |
| 20°C (68°F) | 2.21 to 2.69 kΩ | |
| 60°C (140°F) | 0.49 to 0.67 kΩ |
If the result is not as specified, replace the mass air flow meter.