Home › Engine / Hybrid System › 2NR-FE ENGINE CONTROL › HEATED OXYGEN SENSOR › from 2016.04
RM30M0E _51 Engine / Hybrid System _053304 2NR-FE ENGINE CONTROL _0260044 HEATED OXYGEN SENSOR G

2NR-FE ENGINE CONTROL  HEATED OXYGEN SENSOR  INSPECTION  


PROCEDURE

Hide 89465 1.INSPECT HEATED OXYGEN SENSOR

a.

Check the resistance.

i.
A171222C06
1.885,0.844 2.302,0.427 true 1.104,1.823 1.521,1.406 true 1.542,0.844 1.073,0.469 true 0.146,0.094 0.458,0.25 0.313,0.156 10 false *a 2.354,0.344 2.875,0.573 0.521,0.229 10 false HT1B 0.885,1.74 1.406,1.969 0.521,0.229 10 false E2 0.833,0.375 1.354,0.604 0.521,0.229 10 false +B
*a Component without harness connected
(Heated Oxygen Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 9 to 14 Ω
1 (HT1B) - 4 (E2) Always 10 kΩ or higher


If the result is not as specified, replace the heated oxygen sensor.