Home › General › SPECIFICATIONS › K312 CVT › 2016.04–2017.10
RM30M0E _V1 General _017290 SPECIFICATIONS _0269691 K312 CVT F

SPECIFICATIONS  K312 CVT  SERVICE DATA  


Continuously Variable Transaxle System
Engine stall speed D 2200 +/- 400 rpm
Fluid pressure (Throttle valve fully opened)*1
Engine stall speed
2200 +/- 400 rpm
D 4.2 to 4.9 MPa (42.8 to 50.0 kgf/cm2, 609 to 711 psi)
R 4.0 to 5.1 MPa (40.8 to 52.0 kgf/cm2, 580 to 740 psi)
Time lag N → D Less than 1.2 seconds
N → R Less than 1.5 seconds
Engine idle speed (A/C off) N 680 to 780 rpm
Shift schedule (D)
Throttle valve position (100%) 40 km/h (25 mph) 4400 to 5000 rpm
70 km/h (43 mph) 5200 to 5900 rpm
100 km/h (62 mph) 5600 to 6300 rpm
Throttle valve position (Constant opening angle)*2 40 km/h (25 mph) 800 to 1200 rpm
70 km/h (43 mph) 1100 to 1500 rpm
100 km/h (62 mph) 1500 to 2000 rpm
Shift schedule (D)
Kick down Accelerator pedal fully depressed above 70 km/h (43 mph) 3000 rpm or more
Lock-up point
Lock-up ON
(Accelerator pedal opening 10%)
D 5 to 30 km/h (3 to 19 mph)
Lock-up OFF
(Accelerator pedal opening 0%)
D 5 to 30 km/h (3 to 19 mph)

*1: Connect terminals 13 (TC) and 4 (CG) of the DLC3 when measuring the fluid pressure.

*2: Depress the accelerator pedal at a consistent angle to maintain the specified vehicle speed.

Continuously Variable Transaxle Fluid
Dry fill 7.47 liters (7.9 US qts, 6.6 Imp. qts) Toyota Genuine CVT fluid FE

Continuously Variable Transaxle Assembly
CVT oil pump type T oil seal Standard Depth 0 to 0.5 mm (0 to 0.0197 in.)

Torque Converter and Drive Plate
Drive plate runout Maximum 0.30 mm (0.0118 in.)

Front Differential Oil Seal
Front drive shaft oil seal LH Standard Depth 6.7 to 7.7 mm (0.264 to 0.303 in.)
Front drive shaft oil seal RH Standard Depth 1.5 to 2.5 mm (0.0591 to 0.0984 in.)

Revolution Sensor
Transmission revolution sensor (NIN)
Tester Connection Condition Specified Condition
1 (NIN-) - 2 (NIN+) 20°C (68°F) 560 to 680 Ω
Transmission revolution sensor (NOUT)
Tester Connection Condition Specified Condition
1 (NOTO) - 2 (NOTB) Low Signal 4 to 8 mA
High Signal 12 to 16 mA

Park/Neutral Position Switch
Park/neutral position switch assembly
Tester Connection Condition Specified Condition
4 (B) - 9 (L) Shift lever in P or N Below 1 Ω
Shift lever not in P and N 10 kΩ or higher
1 (RB) - 3 (PL) Shift lever in P Below 1 Ω
Shift lever not in P 10 kΩ or higher
1 (RB) - 2 (RL) Shift lever in R Below 1 Ω
Shift lever not in R 10 kΩ or higher
1 (RB) - 8 (NL) Shift lever in N Below 1 Ω
Shift lever not in N 10 kΩ or higher
1 (RB) - 7 (DL) Shift lever in D or M Below 1 Ω
Shift lever not in D and M 10 kΩ or higher

Shift Lever
Shift lock control unit assembly (w/o Smart entry and start system)
Wire harness
Tester Connection Condition Specified Condition
1 (ACC) - Body ground Ignition switch ACC 11 to 14 V
Ignition switch off Below 1 V
4 (IG) - Body ground Ignition switch ON 11 to 14 V
Ignition switch off Below 1 V
8 (STP) - Body ground Brake pedal depressed 11 to 14 V
Brake pedal released Below 1 V
7 (E) - Body ground Always Below 1 Ω
Key interlock solenoid operation signal
5 (KLS+) - Body ground Ignition switch ACC and shift lever in P Below 1 V
Ignition switch ACC and shift lever not in P 11 to 14 V
Shift lock solenoid
1 (SLS+) - 2 (SLS-) Always 112 Ω
4 (P) - 3 (E2) Shift lever in P 10 kΩ or higher
Shift lever not in P Below 1 Ω
Shift lock control unit assembly (w/ Smart entry and start system)
Wire harness
Tester Connection Condition Specified Condition
4 (IG) - Body ground Engine switch on (IG) 11 to 14 V
Engine switch off Below 1 V
8 (STP) - Body ground Brake pedal depressed 11 to 14 V
Brake pedal released Below 1 V
7 (E) - Body ground Always Below 1 Ω
Shift lock solenoid
1 (SLS+) - 2 (SLS-) Always 112 Ω
4 (P) - 3 (E2) Shift lever in P 10 kΩ or higher
Shift lever not in P Below 1 Ω
Transmission control switch (Shift lock control unit assembly)
Tester Connection Condition Specified Condition
1 (SFTD) - 2 (E) Shift lever held in"-"(Downshift) Below 1 Ω
Shift lever not in"-" 10 kΩ or higher
3 (SFTU) - 2 (E) Shift lever held in"+"(Downshift) Below 1 Ω
Shift lever not in"+" 10 kΩ or higher