16361A
1.INSPECT FAN AND GENERATOR V BELT
Check the fan and generator V belt for wear, cracks or other signs of damage.
If any of the following defects is found, replace the fan and generator V belt.
The fan and generator V belt is cracked.
The fan and generator V belt is worn out to the extent that the cords are exposed.
The fan and generator V belt has chunks missing from the ribs.
| *a | Correct |
| *b | Incorrect |
Check that the fan and generator V belt fits properly in the ribbed grooves.
Check with your hand to confirm that the fan and generator V belt has not slipped out of the grooves on the bottom of the pulley. If it has slipped out, replace the fan and generator V belt. Install a new fan and generator V belt correctly.
| *1 | Crankshaft Damper Sub-assembly |
| *2 | Generator with Regulator Assembly |
| *3 | Engine Water Pump Assembly |
| *4 | Cooler Compressor Assembly |
|
Specified Point |
Inspect the fan and generator V belt deflection and tension.
| Item | Specified Condition |
|---|---|
| New belt | 8.0 to 9.0 mm (0.31 to 0.35 in) |
| Used belt | 12.5 to 13.5 mm (0.49 to 0.53 in) |
| Item | Specified Condition |
|---|---|
| New belt | 700 to 800 N (71 to 82 kg, 157 to 180 lb) |
| Used belt | 300 to 400 N (31 to 41 kg, 67 to 90 lb) |
If the fan and generator V belt deflection is not as specified, adjust it.
When inspecting the fan and generator V belt deflection, apply 98 N (10 kgf) tensile force to it.
Perform the fan and generator V belt inspection and adjustment while the engine is cold.
The fan and generator V belt tension and deflection should be checked immediately after installation of a new fan and generator V belt, and after cranking the engine when inspecting a used belt.
Check the fan and generator V belt deflection at the point between the specified pulleys where the deflection is greatest.
When installing a new fan and generator V belt, set its tension to the intermediate value of the specification.
When inspecting a fan and generator V belt which has been used for over 5 minutes, apply the Used Belt specifications.
When reinstalling a fan and generator V belt which has been used for over 5 minutes, adjust its deflection and tension to the intermediate values of each Used Belt specification.
The fan and generator V belt tension and deflection should be checked after 2 revolutions of engine cranking.
When using a belt tension gauge, confirm its accuracy by using a master gauge first.