Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) › from 2017.10
RM30M0E _58 Vehicle Interior _017118 HEATING / AIR CONDITIONING _0086573 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  DATA LIST / ACTIVE TEST  


DATA LIST


Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

According to the display on the GTS, read the Data List.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler (room temperature sensor) thermistor Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed -
Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed -
Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
Actual ambient temperature displayed -
Evaporator Fin Thermistor No. 1 cooler thermistor Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed -
Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed -
Solar Sensor (D Side) Cooler (solar sensor) thermistor Min.: 0
Max.: 255
Cooler (solar sensor) thermistor value increases as brightness increases -
Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed -
Set Temperature (D Side) Set temperature Min.: MAX COLD
Max.: MAX HOT
Set temperature displayed -
Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -0.4566 MPaG
Max.: 3.2943 MPaG
Actual pressure displayed -
Air Mix Servo Targ Pulse(D) Air mix damper servo sub-assembly target pulse Min.: 128
Max.: 383
for LHD
·

MAX COLD: 257 (pulse)

·

MAX HOT: 183 (pulse)


for RHD
·

MAX COLD: 255 (pulse)

·

MAX HOT: 329 (pulse)


-
Air Mix Servo Actual Pulse(D) Air mix damper servo sub-assembly actual pulse Min.: 128
Max.: 383
for LHD
·

MAX COLD: 257 (pulse)

·

MAX HOT: 183 (pulse)


for RHD
·

MAX COLD: 255 (pulse)

·

MAX HOT: 329 (pulse)


-
Air Outlet Servo Pulse (D) Mode damper servo sub-assembly target pulse Min.: 128
Max.: 383
for LHD
·

FACE: 316 (pulse)

·

B/L: 301 (pulse)

·

FOOT: 278 (pulse)

·

FOOT/DEF: 267 (pulse)

·

DEF: 252 (pulse)


for RHD
·

FACE: 196 (pulse)

·

B/L: 211 (pulse)

·

FOOT: 234 (pulse)

·

FOOT/DEF: 245 (pulse)

·

DEF: 260 (pulse)


-
Air Outlet Servo Actu Pulse(D) Mode damper servo sub-assembly actual pulse Min.: 128
Max.: 383
for LHD
·

FACE: 316 (pulse)

·

B/L: 301 (pulse)

·

FOOT: 278 (pulse)

·

FOOT/DEF: 267 (pulse)

·

DEF: 252 (pulse)


for RHD
·

FACE: 196 (pulse)

·

B/L: 211 (pulse)

·

FOOT: 234 (pulse)

·

FOOT/DEF: 245 (pulse)

·

DEF: 260 (pulse)


-
Air Inlet Damper Targ Pulse Recirculation damper servo sub-assembly target pulse Min.: 128
Max.: 383
for LHD
·

RECIRCULATION: 255 (pulse)

·

FRESH: 270 (pulse)


for RHD
·

RECIRCULATION: 257 (pulse)

·

FRESH: 242 (pulse)


-
Air Inlet Damper Actual Pulse Recirculation damper servo sub-assembly actual pulse Min.: 128
Max.: 383
for LHD
·

RECIRCULATION: 255 (pulse)

·

FRESH: 270 (pulse)


for RHD
·

RECIRCULATION: 257 (pulse)

·

FRESH: 242 (pulse)


-
Refrigerant Gas Type Refrigerant gas type R134a, 1234yf Refrigerant gas type displayed -
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -


ACTIVE TEST


Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

According to the display on the GTS, perform the Active Test.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Magnetic Clutch Relay Magnet clutch relay OFF, ON -
Defogger Relay (Rear) Defogger relay OFF, ON -
Air Mix Servo Targ Pulse(D) Air mix damper servo sub-assembly pulse Min.: 128
Max.: 383
for LHD

Operates between 183 and 257 pulses


for RHD

Operates between 255 and 329 pulses


Air Outlet Servo Pulse (D) Mode damper servo sub-assembly pulse Min.: 128
Max.: 383
for LHD

Operates between 252 and 316 pulses


for RHD

Operates between 196 and 260 pulses


Air Inlet Damper Targ Pulse Recirculation damper servo sub-assembly pulse Min.: 128
Max.: 383
for LHD

Operates between 255 and 270 pulses


for RHD

Operates between 242 and 257 pulses