84930F
1.INSPECT ALL LOCK RELAY (DOOR LOCK CONTROL RELAY)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Battery voltage not applied between terminals | Below 1 Ω |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the all lock relay (door lock control relay).
84930F
2.INSPECT UNLOCK RELAY (DOOR LOCK CONTROL RELAY)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Battery voltage not applied between terminals | Below 1 Ω |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the unlock relay (door lock control relay).
84930F
3.INSPECT D-UNLOCK RELAY (DOOR LOCK CONTROL RELAY)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Battery voltage not applied between terminals | Below 1 Ω |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the d-unlock (door lock control relay).