87106N
1.INSPECT RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for LHD)
| *a | Component without harness connected
(Recirculation Damper Servo Sub-assembly) |
| *b | Fresh side |
| *c | Recirculation side |
| *d | 180° |
| *e | 83°24' +/- 3°30' (83.40° +/- 3.5°) |
Apply battery voltage to the recirculation damper servo sub-assembly and check the operation of the motor.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 1 |
Turns to the "RECIRCULATION" side smoothly |
| Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 2 |
Turns to the "FRESH" side smoothly |
If the result is not as specified, replace the recirculation damper servo sub-assembly.
87106N
2.INSPECT RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for RHD)
| *a | Component without harness connected
(Recirculation Damper Servo Sub-assembly) |
| *b | Fresh side |
| *c | Recirculation side |
| *d | 180° |
| *e | 83°24' +/- 3°30' (83.40° +/- 3.5°) |
Apply battery voltage to the recirculation damper servo sub-assembly and check the operation of the motor.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 1 |
Turns to the "RECIRCULATION" side smoothly |
| Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 2 |
Turns to the "FRESH" side smoothly |
If the result is not as specified, replace the recirculation damper servo sub-assembly.