Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR INLET CONTROL SERVO MOTOR(for TMT Made Manual Air Conditioning System) › 2017.10–2018.01
RM30M0E _58 Vehicle Interior _017118 HEATING / AIR CONDITIONING _0336776 AIR INLET CONTROL SERVO MOTOR(for TMT Made Manual Air Conditioning System) G

HEATING / AIR CONDITIONING  AIR INLET CONTROL SERVO MOTOR(for TMT Made Manual Air Conditioning System)  INSPECTION  


PROCEDURE

Hide 87106N 1.INSPECT RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for LHD)

a.
I113638C02
2.667,1.365 3,1.25 true 0.948,0.052 1.26,0.208 0.313,0.156 10 false *a 2.302,0.906 2.615,1.063 0.313,0.156 10 false *b 0.708,2.5 1.021,2.656 0.313,0.156 10 false *c 2.615,2.646 2.927,2.802 0.313,0.156 10 false *d 3.083,1.156 3.396,1.313 0.313,0.156 10 false *e
*a Component without harness connected
(Recirculation Damper Servo Sub-assembly)
*b Fresh side
*c Recirculation side
*d 180°
*e 83°24' +/- 3°30' (83.40° +/- 3.5°)


Apply battery voltage to the recirculation damper servo sub-assembly and check the operation of the motor.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 1
Turns to the "RECIRCULATION" side smoothly
Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 2
Turns to the "FRESH" side smoothly


If the result is not as specified, replace the recirculation damper servo sub-assembly.



Hide 87106N 2.INSPECT RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for RHD)

a.
I113906C01
0.552,3.104 0.896,2.771 true 0.729,0.063 1.042,0.26 0.313,0.198 10 false *a 1.677,3.156 1.99,3.354 0.313,0.198 10 false *b 1.99,0.875 2.302,1.073 0.313,0.198 10 false *c 0.302,1.771 0.615,1.969 0.313,0.198 10 false *d 0.354,3.073 0.667,3.271 0.313,0.198 10 false *e
*a Component without harness connected
(Recirculation Damper Servo Sub-assembly)
*b Fresh side
*c Recirculation side
*d 180°
*e 83°24' +/- 3°30' (83.40° +/- 3.5°)


Apply battery voltage to the recirculation damper servo sub-assembly and check the operation of the motor.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 1
Turns to the "RECIRCULATION" side smoothly
Battery positive (+) → Terminal 5
Battery negative (-) → Terminal 2
Turns to the "FRESH" side smoothly


If the result is not as specified, replace the recirculation damper servo sub-assembly.