Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING PANEL(for TMT Made Manual Air Conditioning System) › 2017.10–2018.01
RM30M0E _58 Vehicle Interior _017118 HEATING / AIR CONDITIONING _0336796 AIR CONDITIONING PANEL(for TMT Made Manual Air Conditioning System) G

HEATING / AIR CONDITIONING  AIR CONDITIONING PANEL(for TMT Made Manual Air Conditioning System)  INSPECTION  


PROCEDURE

Hide 55900A 1.INSTALL HEATER CONTROL AND ACCESSORY ASSEMBLY

a.

Check the blower resistance.

i.
I109787C09
1.188,3.479 1.031,3.24 true 2.25,3.469 2.448,3.219 true 1.031,4.135 1.188,3.844 true 1.802,3.854 1.979,4.135 true 1.573,3.865 1.542,4.146 true 2.406,3.042 2.719,3.24 0.313,0.198 10 false E 1.458,4.167 1.771,4.365 0.313,0.198 10 false M1 1.938,4.156 2.25,4.354 0.313,0.198 10 false LO 0.927,3.052 1.24,3.25 0.313,0.198 10 false HI 0.938,4.156 1.25,4.354 0.313,0.198 10 false M2 0.469,2.75 0.781,2.948 0.313,0.198 10 false *a 0.469,0.615 0.781,0.813 0.313,0.198 10 false *b 1.156,0.198 1.469,0.396 0.313,0.198 10 false *c 1.979,0.188 2.292,0.385 0.313,0.198 10 false *d 2.74,0.51 3.052,0.729 0.313,0.219 10 false *e 3.156,1.198 3.375,1.385 0.219,0.188 10 false *f
*a Component without harness connected
(Heater Control and Accessory Assembly)
*b Blower Switch OFF Position
*c Blower Switch LO Position
*d Blower Switch M1 Position
*e Blower Switch M2 Position
*f Blower Switch HI Position


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 (LO), 5 (HI), 8 (M1), 10 (M2) - 1 (E) Blower switch: OFF 10 kΩ or higher
7 (LO) - 1 (E) Blower switch: LO Below 1 Ω
7 (LO), 8 (M1) - 1 (E) Blower switch: LO - M1 Below 1 Ω
7 (LO), 8 (M1) - 1 (E) Blower switch: M1 Below 1 Ω
7 (LO), 8 (M1), 10 (M2) - 1 (E) Blower switch: M1 - M2 Below 1 Ω
7 (LO), 10 (M2) - 1 (E) Blower switch: M2 Below 1 Ω
7 (LO), 10 (M2), 5 (HI) - 1 (E) Blower switch: M2 - HI Below 1 Ω
7 (LO), 5 (HI) - 1 (E) Blower switch: HI Below 1 Ω


If the result is not as specified, replace the heater control and accessory assembly.




b.

Check the illumination.

i.
I113907C01
1,1.75 1.25,1.375 true 2.5,1.75 2.198,1.344 true 0.115,0.104 0.427,0.302 0.313,0.198 10 false *a 2.51,1.792 2.906,2.042 0.396,0.25 10 false E 0.854,1.792 1.25,2.042 0.396,0.25 10 false ILL+
*a Component without harness connected
(Heater Control and Accessory Assembly)


Apply battery voltage to the air conditioner control assembly and check that the air conditioner control assembly illuminates.

OK:
Measurement Condition Specified Condition
Battery positive (+) → 16 (ILL+)
Battery negative (-) → 9 (E)
Illuminates


If the result is not as specified, replace the heater control and accessory assembly.




c.

Check the fresh-air/recirculation selector switch indicator.

i.
I113903C03
1.75,0.854 2.104,0.427 true 1.156,2.417 0.74,2.01 true 2.26,2.635 2.677,2.635 true 0.104,0.083 0.417,0.281 0.313,0.198 10 false *a 2.188,0.302 2.5,0.5 0.313,0.198 10 false *b 2.792,2.563 3.104,2.76 0.313,0.198 10 false E 0.583,1.906 0.896,2.104 0.313,0.198 10 false B
*a Component without harness connected
(Heater Control and Accessory Assembly)
*b Indicator


Apply battery voltage to the air conditioner control assembly and check that the indicator illuminates.

OK:
Measurement Condition Switch Condition Specified Condition
Battery positive (+) → 8 (B)
Battery negative (-) → 9 (E)
Fresh-air/recirculation selector switch : ON Indicator illuminates


If the result is not as specified, replace the heater control and accessory assembly.




d.

Check the A/C switch indicator.

i.
I113652C01
1.719,0.823 2.094,0.417 true 1.156,2.417 0.781,1.885 true 1.313,2.688 1.01,3.115 true 0.156,0.146 0.469,0.302 0.313,0.156 10 false *a 2.188,0.302 2.5,0.458 0.313,0.156 10 false *b 0.656,1.719 0.969,1.875 0.313,0.156 10 false B 0.823,3.146 1.198,3.313 0.375,0.167 10 false A/C
*a Component without harness connected
(Heater Control and Accessory Assembly)
*b Indicator


Apply battery voltage to the air conditioner control assembly and check that the indicator illuminates.

OK:
Measurement Condition Switch Condition Specified Condition
Battery positive (+) → 8 (B)
Battery negative (-) → 15 (A/C)
A/C switch : ON Indicator illuminates


If the result is not as specified, replace the heater control and accessory assembly.