89120A
1.INSPECT AUTOMATIC LIGHT CONTROL SENSOR
| *a | Front view of wire harness connector
(to Automatic Light Control Sensor) |
Disconnect the E1 automatic light control sensor connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E2-1 (CLTB) - E2-2 (CLTE) | Ignition switch off | Below 1 V |
| E2-1 (CLTB) - E2-2 (CLTE) | Ignition switch ON | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E2-2 (CLTE) - Body ground | Always | Below 1 Ω |
If the result is not as specified, there may be a malfunction on the wire harness side.
| *a | Component with harness connected
(Automatic Light Control Sensor) |
Reconnect the E1 automatic light control sensor connector.
Connect an oscilloscope to the automatic light control sensor connector.
Check the waveform.
| Tester Connection | Tool Setting | Condition | Specified Condition |
|---|---|---|---|
| E2-4 (CLTS) - E1-2 (CLTE) | 2 V/DIV., 10 ms./DIV. | Ignition switch ON, light control switch in AUTO position | Correct waveform is as shown |
The communication waveform changes according to the surrounding brightness.
If the result is not as specified, the automatic light control sensor may be malfunctioning.