The blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.
Inspect the fuses for circuits related to this system before performing the following procedure.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0, Max.: 31 | - |
| Tester Display |
|---|
| Blower Motor |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (Blower motor with fan sub-assembly does not operate) | B |
| NG (Blower motor with fan sub-assembly operates but does not change speed) | C |
A
B
C
Remove the HTR relay from the No. 3 relay block.
Inspect the HTR relay.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the blower motor with fan sub-assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>REMOVAL
Inspect the blower motor with fan sub-assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the HTR relay from the No. 3 relay block.
| *1 | No. 3 Relay Block |
| *a | HTR Relay Holder |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Relay terminal 2 - Body ground | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |
| Relay terminal 5 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the HTR relay from the No. 3 relay block.
Disconnect the F53 blower motor with fan sub-assembly connector.
Disconnect the F56 blower motor control connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Relay terminal 3 - F53-2 | Always | Below 1 Ω |
| Relay terminal 3 - F56-2 (+B) | Always | Below 1 Ω |
| Relay terminal 3 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F53 blower motor with fan sub-assembly connector.
Disconnect the F56 blower motor control connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F56-1 (VN) - F53-1 | Always | Below 1 Ω |
| F56-4 (GND) - Body ground | Always | Below 1 Ω |
| F56-1 (VN) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F3 air conditioning amplifier assembly connector.
Remove the HTR relay from the No. 3 relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F3-20 (HR) - Relay Terminal 1 | Always | Below 1 Ω |
| F3-14 (GND) - Body ground | Always | Below 1 Ω |
| F3-20 (HR) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F3 air conditioning amplifier assembly connector.
Disconnect the F56 blower motor control connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F3-22 (BLW) - F56-3 (SI) | Always | Below 1 Ω |
| F3-22 (BLW) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the air conditioning amplifier assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL
Reconnect the F3 and z2 air conditioning amplifier assembly connectors.
Reconnect the blower motor with fan sub-assembly connector.
Reconnect the blower motor control connector.
Reinstall the heater blower motor relay.
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| F3-20 (HR) - Body ground | Ignition switch ON Blower switch off | 11 to 14 V |
| F3-20 (HR) - Body ground | Ignition switch ON Blower switch LO | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the air conditioning amplifier assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING AMPLIFIER>REMOVAL
Reconnect the F3 and z2 air conditioning amplifier assembly connectors.
Turn the ignition switch to ON.
Turn the blower switch on (LO).
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Measure the waveform between terminal F3-22 (BLW) of the air conditioning amplifier assembly and body ground.
Waveform is similar to that shown in the illustration.
The waveform varies with the blower speed.
| Item | Content |
|---|---|
| Tool setting | 1 V/DIV., 50 μs./DIV. |
| Vehicle condition | Ignition switch ON
Blower switch: LO |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the blower motor control.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER MOTOR CONTROLLER>REMOVAL
Operate the blower motor with fan sub-assembly to check that it function properly.
Blower motor with fan sub-assembly operates normally.
| Proceed to |
|---|
| OK |
| NG |
OK
NG