FUNCTION OF MAIN COMPONENTS
The main components of the air conditioning system have the following functions.
| Component | Function |
|---|---|
| Heater Control and Accessory Assembly | Allows operation and adjustment of the air conditioning system via switches. |
| Air Conditioning Amplifier Assembly*1 | Transmits and receives data to and from the switches and sensors, and controls the air conditioning system. |
| Cooler Compressor Assembly*1 | A compact, lightweight, and low-noise 10-cylinder swash plate type cooler compressor is used. |
| Cooler Condenser Assembly*1 | A cooler condenser is used to improve heat exchange efficiency. |
| Blower Motor with Fan Sub-assembly | The fan blades are thin, and improve air flow inside the blower fan, contributing to the reduction of noise. |
| Heater Radiator Assembly | A Straight Flow Aluminum-II (SFA-II) heater radiator is used for compactness and high performance. |
| No. 1 Cooler Evaporator Sub-assembly | A Beneficial Refrigerant Stream (BRS) evaporator is used for compactness. |
| No. 1 Cooler Thermistor | Detects the temperature of the cool air past the No. 1 cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly. |
| Thermistor Assembly | Detects ambient temperature and outputs it to the combination meter assembly. |
| Recirculation Damper Servo Sub-assembly | Receives the input of the operation signals from the heater control and accessory assembly, operates the motor, and opens and closes the dampers. |
| Air Conditioner Pressure Sensor*1 | Detects the refrigerant pressure and sends the data to the air conditioning amplifier assembly. |
| ECM | Transmits the air conditioning off request signal to the air conditioning amplifier assembly. |
*1: w/ Cooler System
SYSTEM CONTROL
The air conditioning system has the following controls.
| Control | Outline |
|---|---|
| Diagnosis | A Diagnostic Trouble Code (DTC) is stored in memory when the air conditioning amplifier assembly detects a problem with the air conditioning system. |
MODE POSITION AND DAMPER OPERATION
Mode Position and Damper Operation.
| Control Damper | Operation Position | Damper Position | Operation |
|---|---|---|---|
| Air Inlet Control Damper | FRESH | A | Allows fresh air to enter. |
| RECIRCULATION | B | Causes internal air to recirculate. | |
| Air Mix Control Damper | MAX COLD to MAX HOT Temperature Setting | C - D | Varies the mixture ratio of warm air and cool air in order to regulate the temperature continuously between hot and cold. |
| Air Outlet Control Damper | FACE
|
E | Air blows out of the front center registers and side registers. In addition, air blows out slightly from the front footwell register ducts. |
BI-LEVEL
|
F | Air blows out of the front footwell register ducts, front center registers and side registers. | |
FOOT
|
G | Air blows out of the side registers, front footwell register ducts and defroster. In addition, air blows out slightly from the front center registers. | |
FOOT / DEF
|
H | Air blows out of the side registers, front footwell register ducts and defroster. In addition, air blows out slightly from the front center registers. | |
DEF
|
I | Air blows out of the defroster and side registers. In addition, air blows out slightly from the front center registers and front footwell register ducts. |
AIR OUTLETS AND AIRFLOW VOLUME
for LHD
Air Outlets and Airflow Volume.
| Indication | Mode | FACE | FOOT | DEF | |
|---|---|---|---|---|---|
| CTR | SIDE | C | D | ||
| A | B | ||||
|
FACE |
|
|
|
|
|
BI-LEVEL |
|
|
|
|
|
FOOT |
|
|
|
|
|
FOOT / DEF |
|
|
|
|
|
DEF |
|
|
|
|
The size of each circle ○ indicates the ratio of airflow volume.
for RHD
Air Outlets and Airflow Volume.
| Indication | Mode | FACE | FOOT | DEF | |
|---|---|---|---|---|---|
| CTR | SIDE | C | D | ||
| A | B | ||||
|
FACE |
|
|
|
|
|
BI-LEVEL |
|
|
|
|
|
FOOT |
|
|
|
|
|
FOOT / DEF |
|
|
|
|
|
DEF |
|
|
|
|
The size of each circle ○ indicates the ratio of airflow volume.