RM30M0E
_V1
General
_017290
SPECIFICATIONS
_0275177
1NR-FE COOLING
F
SPECIFICATIONS 1NR-FE COOLING SERVICE DATA
COOLANT
| Capacity
|
|
Classification
|
| Cntinuosly Variable Transaxle
|
4.7 liters (5.0 US qts, 4.1 Imp. qts)
|
Use only "TOYOTA Super Long Life Coolant", or similar high qualityethylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of lowphosphates and organic acids).
|
| Manual Transaxle
|
4.6 liters (4.9 US qts, 4.0Imp. qts)
|
Thermostat
| Condition
|
Specified Condition
|
| Standard valve opening temperature
|
80 to 84°C (186 to 183°F)
|
| Standard valve lift
|
8.5 mm (0.335 in.) or more at 95°C (203°F)
|
Cooling Fan Motor
| Item
|
Condition
|
Specified Condition
|
| Cooling fan motor
|
Battery voltage applied at 20°C (68°F)
|
12.4 to 15.4 A
|
Cooling Fan Resistor
| Item
|
Tester Connection
|
Condition
|
Specified Condition
|
| Cooling fan motor
|
1 - 2
|
Battery voltage applied at 20°C (68°F)
|
1.17 to 1.43 Ω
|
Radiator
| Item
|
Condition
|
Specified Condition
|
| Radiator Cap Sub-assembly
|
Standard pressure
(for brand-new radiator cap sub-assembly)
|
93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)
|
Minimum pressure
(for used radiator cap sub-assembly)
|
78.5 kPa (0.8 kgf/cm2, 11.4 psi)
|
Relay
| Item
|
Tester Connection
|
Condition
|
Specified Condition
|
| FAN NO. 1 relay
|
3 - 5
|
Battery voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Battery voltage applied between terminals 1 and 2
|
Below 1 Ω
|
| FAN NO. 2 relay
|
3 - 4
|
Battery voltage not applied between terminals 1 and 2
|
Below 1 Ω
|
| Battery voltage applied between terminals 1 and 2
|
10 kΩ or higher
|
| 3 - 5
|
Battery voltage not applied between terminals 1 and 2
|
10 kΩ or higher
|
| Battery voltage applied between terminals 1 and 2
|
Below 1 Ω
|