Home › Vehicle Exterior › BODY PANEL › CENTER BODY PILLAR (for 3 Door) › from 2020.09
BM36W0E _01 Vehicle Exterior _088117 BODY PANEL _0449245 CENTER BODY PILLAR(for 3 Door) F

BODY PANEL  CENTER BODY PILLAR(for 3 Door)  CUT AND JOIN REPLACEMENT SECTIONS  


K159796

With the quarter panel assembly removed.


REMOVAL


Symbol Meaning
K108818

Remove Weld Points
K108820

Remove Weld Points
K108827

Cut and Join Location

a.

Do not butt weld or heat repair because the heat decreases the strength of areas where ultra high strength steel is used. (See the introduction)


b.

Remove the A.

HINT:

A is reused.


K158946C01
2.208,0.906 2,0.25 2,0.25 1.833,0.25 false 4.25,1.865 4.563,2.021 0.313,0.156 10 false *b 1.688,0.188 2,0.344 0.313,0.156 10 false A 1.594,1.51 1.906,1.667 0.313,0.156 10 false *a 4.458,0.375 4.771,0.531 0.313,0.156 10 false *c
*a 105 mm (4.13 in.) *b 265 mm (10.43 in.)
*c 20 mm (0.79 in.) - -



c.

Roughly cut open the panel so that the adhesive can be reached. Cut through the adhesive with a cut chisel to remove the panel.

HINT:

In cases where the adhesive cannot be removed with a cut chisel, heat the adhesive with an industrial heater gun or gas burner taking care not to cause panel deformation by overheating.


K158949C01
0,0 0,0 false
K108837

Adhesive - -



d.

Remove the center body pillar reinforcement sub-assembly.

K158947C01
2.031,3.802 1.781,4.385 1.781,4.385 1.615,4.385 false 1.427,4.323 1.74,4.479 0.313,0.156 10 false *1
*1 CENTER BODY PILLAR REINFORCEMENT SUB-ASSEMBLY - -



e.

Remove the center body pillar reinforce sub-assembly lower.

K158948C01
3.906,2.281 4.167,1.833 4.167,1.833 4.333,1.833 false 4.396,1.771 4.708,1.927 0.313,0.156 10 false *1 4.042,0.781 4.354,0.938 0.313,0.156 10 false *a 5.51,2.865 5.823,3.021 0.313,0.156 10 false *b
*1 CENTER BODY PILLAR REINFORCE SUB-ASSEMBLY LOWER - -
*a 50 mm (1.97 in.) *b 45 mm (1.77 in.)




INSTALLATION


Symbol Meaning
K108821

Spot Weld
K108823

Plug Weld
K108825

Plug Weld
K108831

Butt Weld

a.

Inspect the fitting of the related parts around the new parts before welding. This affects the appearance of the finish.


b.

Temporarily install the new parts and measure each part of the new parts in accordance with the body dimension diagram. (See the body dimensions)


c.

Weld the center body pillar reinforce sub-assembly lower to the vehicle side.

K158951C01
3.854,2.042 4.167,1.583 4.167,1.583 4.333,1.583 false 4.396,1.521 4.708,1.677 0.313,0.156 10 false *1
*1 CENTER BODY PILLAR REINFORCE SUB-ASSEMBLY LOWER - -



d.

Apply adhesive (3MTM AutomixTM Panel Bonding Adhesive #8115).

HINT:
·

Do not apply adhesive around the plug welding points.

·

Minimize squeeze out in plug welding areas.



K158949C01
0,0 0,0 false
K108837

Adhesive - -



e.

Weld the center body pillar reinforcement sub-assembly to the vehicle side.

K158950C01
1.667,4.5 1.833,4.5 1.833,4.5 2.083,3.802 false 1.479,4.448 1.792,4.646 0.313,0.198 10 false *1
*1 CENTER BODY PILLAR REINFORCEMENT SUB-ASSEMBLY - -
*a Ultra High Strength Steel Welding Point *b Ultra High Strength Steel Welding Point


Follow the welding conditions below when welding ultra high strength steel to assure sufficient weld strength. (When repairing this model)

When welding 2 panels together including 980 MPa ultra high strength steel.

*a: Spot weld Pressure 2940 N (300 kgf, 661 lbf)
Weld current 10000 A
Weld time 18 Cyc.(0.34 Sec.)
*b: Plug weld Plug diameter 10 mm (0.39 in.)
Wire type AWS A5.18 ER70S-6/ER70S-3
Shield gas Metal active gas

NOTICE:

Be sure to use Metal active gas (Ar + CO2 20 to 30% or Ar + O2 2%) as the shield gas when plug welding. Sufficient weld strength cannot be assured when using 100% CO2 shield gas.




f.

Weld the A to the vehicle side.

K158952C01
3.563,0.948 3.75,0.333 3.75,0.333 3.917,0.333 false 4,0.281 4.156,0.479 0.156,0.198 10 false A
*a Ultra High Strength Steel Welding Point - -


Follow the welding conditions below when welding ultra high strength steel to assure sufficient weld strength. (When repairing this model)

When welding 3 panels or more together including 980 MPa ultra high strength steel. (When plug welding a third panel to 2 panels which are welded under the conditions described above.)

*a: Plug weld Plug diameter Same as the standard method (See the introduction)
Wire type AWS A5.18 ER70S-6/ER70S-3
Shield gas Metal active gas

NOTICE:

Be sure to use Metal active gas (Ar + CO2 20 to 30% or Ar + O2 2%) as the shield gas when plug welding. Sufficient weld strength cannot be assured when using 100% CO2 shield gas.




g.

After welding, apply the foamed sealing material to the corresponding parts. (See the painting/coating)


h.

After applying the top coat, apply anti-rust agent to the internal panel portion of the closed section structural weld points.