With the cowl top side upper panel assembly and roof panel assembly removed.
REMOVAL
| Symbol Meaning | |
|---|---|
|
Remove Weld Points |
|
Remove Weld Points |
|
Remove Weld Points |
|
Cut with Disc Sander etc. |
|
Cut Location for Supply Parts |
Do not butt weld or heat repair because the heat decreases the strength of areas where ultra high strength steel is used. (See the introduction)
Roughly cut open the panel so that the adhesive can be reached. Cut through the adhesive with a cut chisel to remove the panel.
In cases where the adhesive cannot be removed with a cut chisel, heat the adhesive with an industrial heater gun or gas burner taking care not to cause panel deformation by overheating.
|
Adhesive | - | - |
Remove the side panel sub-assembly inner.
| *1 | SIDE PANEL SUB-ASSEMBLY INNER | - | - |
| *A | for Standard Roof | *B | for Panoramic Moon Roof |
Roughly cut open the panel so that the adhesive can be reached. Cut through the adhesive with a cut chisel to remove the panel.
In cases where the adhesive cannot be removed with a cut chisel, heat the adhesive with an industrial heater gun or gas burner taking care not to cause panel deformation by overheating.
|
Adhesive | - | - |
Remove the front body pillar sub-assembly outer and front pillar reinforcement sub-assembly lower.
| *1 | FRONT BODY PILLAR SUB-ASSEMBLY OUTER | *2 | FRONT PILLAR REINFORCEMENT SUB-ASSEMBLY LOWER |
| *A | for Standard Roof | *B | for Panoramic Moon Roof |
INSTALLATION
| Symbol Meaning | |
|---|---|
|
Plug Weld |
|
Plug Weld |
|
Plug Weld |
|
Fillet Weld |
|
Butt Weld |
|
Body Sealer |
Inspect the fitting of the related parts around the new parts before welding. This affects the appearance of the finish.
Temporarily install the new parts and measure each part of the new parts in accordance with the body dimension diagram. (See the body dimensions)
Before temporarily installing the new parts, weld the front body pillar sub-assembly outer and front pillar reinforcement sub-assembly lower with the standard number of welding points.
| *1 | FRONT BODY PILLAR SUB-ASSEMBLY OUTER | *2 | FRONT PILLAR REINFORCEMENT SUB-ASSEMBLY LOWER |
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 2 panels together including 1500 MPa or 980 MPa ultra high strength steel.
| *a: Plug weld | Plug diameter | 10 mm (0.39 in.) |
| Wire type | AWS A5.18 ER70S-6/ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar + CO2 20 to 30% or Ar + O2 2%) as the shield gas when plug welding. Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
Apply adhesive (3MTM AutomixTM Panel Bonding Adhesive #8115).
Do not apply adhesive around the plug welding points.
Minimize squeeze out in plug welding areas.
|
Adhesive | - | - |
Weld the front body pillar sub-assembly outer and front pillar reinforcement sub-assembly lower to the vehicle side.
| *1 | FRONT BODY PILLAR SUB-ASSEMBLY OUTER | *2 | FRONT PILLAR REINFORCEMENT SUB-ASSEMBLY LOWER |
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 2 panels together including 1500 MPa or 1180 MPa or 980 MPa ultra high strength steel.
| *a: Plug weld | Plug diameter | 10 mm (0.39 in.) |
| Wire type | AWS A5.18 ER70S-6/ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar + CO2 20 to 30% or Ar + O2 2%) as the shield gas when plug welding. Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 2 panels together including 980 MPa ultra high strength steel.
| *a: Plug weld | Plug diameter | 10 mm (0.39 in.) |
| Wire type | AWS A5.18 ER70S-6/ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar + CO2 20 to 30% or Ar + O2 2%) as the shield gas when plug welding. Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
| *A | for Standard Roof | *B | for Panoramic Moon Roof |
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 2 panels together including 1500 MPa or 1180 MPa ultra high strength steel.
| *a: Plug weld | Plug diameter | 10 mm (0.39 in.) |
| Wire type | AWS A5.18 ER70S-6/ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar + CO2 20 to 30% or Ar + O2 2%) as the shield gas when plug welding. Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
| *a | 11 mm (0.43 in.) | - | - |
Before installing a new part, apply body sealer.
Apply body sealer in an even, continuous bead.
Apply adhesive (3MTM AutomixTM Panel Bonding Adhesive #8115).
Do not apply adhesive around the plug welding points.
Minimize squeeze out in plug welding areas.
|
Adhesive | - | - |
Weld the side panel sub-assembly inner to the vehicle side.
| *1 | SIDE PANEL SUB-ASSEMBLY INNER | - | - |
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 3 panels or more together including 1500 MPa or 980 MPa ultra high strength steel. (When plug welding a third panel to 2 panels which are welded under the conditions described above.)
| *a: Plug weld | Plug diameter | Same as the standard method (See the introduction) |
| Wire type | AWS A5.18 ER70S-6/ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar + CO2 20 to 30% or Ar + O2 2%) as the shield gas when plug welding. Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 3 panels or more together including 980 MPa ultra high strength steel. (When plug welding a third panel to 2 panels which are welded under the conditions described above.)
| *a: Plug weld | Plug diameter | Same as the standard method (See the introduction) |
| Wire type | AWS A5.18 ER70S-6/ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar + CO2 20 to 30% or Ar + O2 2%) as the shield gas when plug welding. Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
| *A | for Standard Roof | *B | for Panoramic Moon Roof |
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 3 panels or more together including 1500 MPa ultra high strength steel. (When plug welding a third panel to 2 panels which are welded under the conditions described above.)
| *a: Plug weld | Plug diameter | Same as the standard method (See the introduction) |
| Wire type | AWS A5.18 ER70S-6/ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar + CO2 20 to 30% or Ar + O2 2%) as the shield gas when plug welding. Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
After welding, apply the foamed sealing material to the corresponding parts. (See the painting/coating)
After welding, apply body sealer to the corresponding parts. (See the painting/coating)
After applying the top coat, apply anti-rust agent to the internal panel portion of the closed section structural weld points.