OUTLINE
A semiconductor power integration system that combines multiple relays and fuses is used, achieving compactness and quietness.
A multiplex communication function (CXPI communication line) is installed to the semiconductor power integration system to achieve a reduction in relay operation signal lines. Also, the fuse condition (blown fuse or not) is now able to be confirmed using the GTS, achieving superior serviceability.
See the MULTIPLEX COMMUNICATION SYSTEM [CXPI] section for the details of the CXPI communication line.
A scene-based power supply system controls the supply of power to each system in the vehicle according to vehicle conditions.
In a situation where the vehicle is making an "emergency shutdown while driving", the supply of power is stopped only to the systems which generate motive force, and supply of power to other systems continues until the vehicle comes to a stop. As a result, only the systems which generate motive force are stopped, while the operation of other systems can continue until the vehicle comes to a stop.
An "emergency shutdown while driving" refers to a situation when the following actions are performed while the vehicle is being driven:
Vehicles without smart entry and start system: The ignition key is turned from the ON position to the ACC position.
Vehicles with smart entry and start system: The engine switch (gasoline models) or power switch (HV models) is pressed and held for 2 seconds or more, or pressed quickly 3 times.