FUNCTION OF MAIN COMPONENTS


a.

The air conditioning system consists of the following parts:

Component Function

*1: Models with automatic air conditioning system

*2: Models with manual air conditioning system

*3: Gasoline models

*4: HV models

Air Conditioning Control Assembly*1 Allows operation and adjustment of the air conditioning system via switches.
No. 1 Heater Control Sub-assembly*2 Allows operation and adjustment of the air conditioning system via switches.
No. 2 Heater Control Sub-assembly*2
No. 3 Heater Control Sub-assembly*2
Air Conditioning Amplifier Assembly Transmits and receives data between the switches and sensors.
Compressor with Pulley Assembly*3
·

Performs suction, compression and discharge of refrigerant gas.

·

A continuously variable capacity type cooler compressor is used to steplessly control the refrigerant discharge capacity.


Compressor with Motor Assembly*4
·

Performs suction, compression and discharge of refrigerant gas.

·

The compressor with motor assembly is driven by an electric motor.


Blower Motor with Fan Sub-assembly High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly.
No. 1 Air Conditioning Radiator Damper Servo Sub-assembly*1 Damper Servo (Mode Switching)*3 Controlled by the air conditioning amplifier assembly to move the mode control damper and switch the registers.
Damper Servo (Driver Seat Air Mix) Controlled by the air conditioning amplifier assembly to move the driver seat air mix control damper.
No. 1 Blower Damper Servo Sub-assembly*1 Damper Servo (Fresh/Recirculation Damper) Driven by the air conditioning amplifier assembly to move the fresh/recirculation damper.
Evaporator Temperature Sensor (No. 1 Cooler Thermistor) Detects the temperature of the cool air past the No. 1 cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly.
Ambient Temperature Sensor (Thermistor Assembly)*1 Detects ambient temperature and outputs it to the air conditioning amplifier assembly.
Cooler (Room Temperature Sensor) Thermistor*1 Detects room temperature and outputs it to the air conditioning amplifier assembly.
Automatic Light Control Sensor Detects the changes in the amount of solar energy and outputs them to the air conditioning amplifier assembly via the main body ECU (multiplex network body ECU).
Air Conditioner Pressure Sensor Detects the refrigerant pressure and outputs data to the air conditioning amplifier assembly.
ECM Receives the signals from the engine coolant temperature sensor and transmits them to the air conditioning amplifier assembly.
Hybrid Vehicle Control ECU Assembly*4
·

Transmits the drive mode control signal to the air conditioning amplifier assembly.

·

Controls the compressor with motor assembly in accordance with the state of the air conditioning system and hybrid control system.


Combination Meter Assembly Transmits the vehicle speed signal to the air conditioning amplifier assembly.
Main Body ECU (Multiplex Network Body ECU) Receives the signals from the automatic light control sensor and transmits them to the air conditioning amplifier assembly.



SYSTEM CONTROL


a.

Control List

Models with Manual Air Conditioning System
Control Outline
Refrigerant Volume Detection Control Judges a shortage of refrigerant volume based on signals from each sensor and informs the user by turning off the indicator light of the A/C switch.
Compressor Control (Cooler Compressor Assembly) Controls the cooler compressor assembly to turn it on or off and adjust the discharge capacity based on the signals from various sensors.

Models with Automatic Air Conditioning System
Control Outline

*1: Gasoline models

*2: HV models

Neural Network Control This control is capable of effecting complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input/output relationship that is similar to a human brain.
Outlet Air Temperature Control Based on the temperature set by the temperature control switches, the neural network control calculates the outlet air temperature based on the input signals from various sensors.
Blower Control Controls the blower motor in accordance with the airflow volume that has been calculated by neural network control based on the input signals from various sensors.
Air Outlet Control
·

Automatically switches the air outlets in accordance with the outlet mode that has been calculated by neural network control based on the input signals from various sensors.

·

In accordance with the engine coolant temperature, outside air temperature, amount of sunlight, required blower, outlet temperature and vehicle speed conditions, this control automatically switches the blower outlet to FOOT/DEF mode to prevent the windows from becoming fogged when the outside air temperature is low.


Air Inlet Control
·

Automatically controls the air inlet control damper to achieve the calculated outlet air temperature that is required.

·

Drives the No. 1 blower damper servo sub-assembly (fresh/recirculation damper) in accordance with the operation of the air inlet control switch and moves the dampers to the FRESH or RECIRC position.


ECO Drive Mode Control
·

When ECO drive mode is selected, the air conditioning amplifier assembly enters ECO air conditioning mode.

·

Pressing the ECO air conditioning mode switch cancels the ECO air conditioning mode.


Refrigerant Volume Detection Control Judges a shortage of refrigerant volume based on signals from various sensors and informs the user by turning off the indicator light of the A/C switch.
Compressor Control (Compressor with Pulley Assembly)*1
·

The air conditioning amplifier assembly controls the compressor discharge capacity by adjusting the position of the solenoid control valve. The target discharge capacity of the compressor is calculated from signals from various sensors, including:

-

Room temperature sensor

-

Ambient temperature sensor

-

Evaporator temperature sensor

-

Solar sensor


·

Turns the air conditioning on automatically when the AUTO button is pressed when the blower is on and the air conditioning is off.


Compressor Control (Compressor with Motor Assembly)*2
·

The air conditioning amplifier assembly controls the compressor motor speed. The target speed of the compressor is calculated from signals from various sensors, including:

-

Room temperature sensor

-

Ambient temperature sensor

-

Evaporator temperature sensor

-

Solar sensor


·

Turns the air conditioning on automatically when the AUTO button is pressed when the blower is on and the air conditioning is off.

·

Decreases the compressor speed in order to ensure quietness when the vehicle is stopped or the engine is off.


Parking Fresh Control By automatically switching to fresh air mode when the vehicle is parked, ventilation of the parked vehicle is facilitated and outside air is introduced into the air conditioner unit assembly.


b.

Neural Network Control

i.

In the previous automatic air conditioning system, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with a calculation formula that had been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, but extremely uncomfortable in a hot climate. Therefore, as a technique for performing a high level of control, a neural network is used in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly, which effects control to provide enhanced air conditioning comfort.


ii.

The neural network control consists of neurons in an input layer, an intermediate layer, and an output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight and the room temperature based on the signals of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of this data is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor with fan sub-assembly in accordance with the control volumes that have been calculated by neural network control.

Y128416E01
2.99,0.073 4.208,0.396 1.219,0.323 10 false Intermediate Layer 3.958,0.385 5.177,0.708 1.219,0.323 10 false Output Layer 2.396,0.385 3.615,0.708 1.219,0.323 10 false Input Layer 4.594,0.74 6.354,1.094 1.76,0.354 10 false Target Output Temperature 1.188,0.74 2.948,1.094 1.76,0.354 10 false Ambient Temperature 1.323,1.406 2.677,1.781 1.354,0.375 10 false Amount of Sunlight 1.333,2.01 2.688,2.385 1.354,0.375 10 false Room Temperature 2.677,3.125 3.177,3.438 0.5,0.313 10 false Control 0.313,4.083 1.448,4.427 1.135,0.344 10 false Input Processing 2.333,3.563 3.531,3.865 1.198,0.302 10 false Neural Networking 2.49,4.104 3.333,4.521 0.844,0.417 10 false Target Outlet Temperature 0.385,5.25 1.198,5.802 0.813,0.552 10 false Temperature Setting 0.375,6.51 1.208,6.823 0.833,0.313 10 false Sensor Input 0.385,7.583 1.219,7.896 0.833,0.313 10 false Switch Input 0.594,8.458 2.698,8.771 2.104,0.313 10 false : Neural network operation range 2.313,4.896 3.5,5.344 1.188,0.448 10 false Amount of Sunlight Correction 2.479,5.698 3.344,6.271 0.865,0.573 10 false Target Airflow Volume 2.51,6.531 3.313,6.823 0.802,0.292 10 false Outlet Mode 2.583,7.281 3.24,7.563 0.656,0.281 10 false Inlet Mode 2.531,7.823 3.375,8.104 0.844,0.281 10 false Compressor 3.969,4.583 5.24,5.052 1.271,0.469 10 false Temperature Control Correction 3.865,5.708 5.365,6.208 1.5,0.5 10 false Various Types of Airflow Volume Corrections 3.906,6.427 5.344,6.938 1.438,0.51 10 false Various Types of Mode Corrections 4.063,7.167 5.135,7.698 1.073,0.531 10 false Various Types of Corrections 5.792,4.094 6.927,4.438 1.135,0.344 10 false Output Correction 5.885,4.635 6.833,5.125 0.948,0.49 10 false Air Mix Control Damper 5.917,5.833 6.813,6.135 0.896,0.302 10 false Blower Motor 5.938,6.438 6.771,6.958 0.833,0.521 10 false Mode Control Damper 5.854,7.146 6.823,7.656 0.969,0.51 10 false Air Inlet Control Damper 5.958,7.875 6.802,8.156 0.844,0.281 10 false Compressor



c.

ECO Drive Mode Control

i.

During ECO drive mode, the air conditioning amplifier assembly restricts the air conditioning system performance under specified conditions, thus improving fuel economy.


ii.

The ECO drive mode control is activated when the combination switch assembly (drive mode select) is operated, and then restricts the air conditioning system performance as described below:

Control Outline

*: HV models

Inside/Outside Air Switch Control If the outside air temperature exceeds a certain limit, the mode switches to inside air recirculation.
Blower Level Control In AUTO mode, the blower level is lowered to the specified value and control is performed. Also, when in warm-up control, the blower level decreases.
Heater and Compressor Control* The operation of the heater or the compressor with motor assembly is decreased, to a reserved operation level.



d.

Refrigerant Volume Detection Control

i.

The air conditioning amplifier assembly judges the volume of refrigerant from the ambient temperature, refrigerant pressure and the temperature of the cool air just past the No. 1 cooler evaporator sub-assembly. When the air conditioning amplifier assembly judges that there is a refrigerant shortage, it turns off the indicator light of the A/C switch. At that time, the compressor with pulley assembly stops operating.



e.

Parking Fresh Control

i.

While parking, fresh air introduction mode is automatically selected to enhance ventilation and reduce any odor remaining in the air conditioning unit, thus odor during engine start-up is minimized.

Timing Chart (Sample)
Y167022E22
1.229,2.854 3.521,3.104 2.292,0.25 10 false : When last mode is fresh air mode 1.229,3.146 3.917,3.542 2.688,0.396 10 false : When last mode is recirculated air mode 1.948,2.302 2.844,2.729 0.896,0.427 10 false Engine/Power Switch Off 2.979,2.302 3.583,2.531 0.604,0.229 10 false 1 Minute 4.417,2.313 5.333,2.729 0.917,0.417 10 false Engine/Power Switch ON 5.792,2.354 6.719,2.813 0.927,0.458 10 false Time (min.) 3.365,0.25 4.719,0.667 1.354,0.417 10 false Fresh air introduction while parking mode 1.688,0.365 2.51,0.615 0.823,0.25 10 false Last Mode 0.958,1.031 1.781,1.281 0.823,0.25 10 false Fresh air 0.573,1.542 2.083,1.771 1.51,0.229 10 false Recirculated air 0.094,1.25 0.865,1.479 0.771,0.229 10 false Air Inlet




DIAGNOSIS


a.

The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation malfunctions in the air conditioning system in memory in the form of Diagnostic Trouble Codes (DTCs). For details, refer to the Repair Manual.