CONSTRUCTION
Depending on models, an inside-and-outside dual air layer type air conditioning unit is used. This type of air conditioning unit introduces outside air to the upper side and circulates inside air to the lower side, thus achieving anti-fogging performance and ventilation loss reduction.
A semi-center location air conditioning radiator assembly, in which the evaporator and heater radiator unit sub-assembly are placed in the vehicle's longitudinal direction, is used. As a result, the air conditioning radiator assembly has been made compact and lightweight.
A compact wide-angle high flow defroster that gives the defroster nozzle assembly inner wall a radial shape is used to ensure superior defroster performance.
| *1 | Air Conditioning Unit Assembly | - | - |
| *a | The illustration shown is an example only. | - | - |
| *1 | Center Register Duct | *2 | Front Defroster Duct |
| *3 | Front Passenger Side Register Duct | *4 | Front Passenger Side Defroster Duct |
| *5 | Front Passenger Side Footwell Duct | *6 | Driver Side Footwell Duct |
| *7 | Driver Side Register Duct | *8 | Driver Side Defroster Duct |
| *a | The illustration shown is an example only. | - | - |
OPERATION
Mode Position and Damper Operation (Models with Single Air Layer Type Air Conditioning Unit)
| *1 | Air Inlet Control Damper | *2 | Blower Motor with Fan Sub-assembly |
| *3 | No. 1 Cooler Evaporator Sub-assembly | *4 | Air Mix Control Damper |
| *5 | Front Passenger Side Register | *6 | Center Register |
| *7 | Driver Side Register | *8 | Mode Switching Damper |
| *9 | Front Passenger Side Footwell Register | *10 | Driver Side Footwell Register |
| *11 | Heater Radiator Unit Sub-assembly | *12 | Front Defroster |
| *13 | Driver Side Defroster | *14 | Front Passenger Side Defroster |
| *a | This illustration shows the dampers and air outlets schematically. It will differ from the actual. | - | - |
|
Fresh Air |
|
Recirculated Air |
| Control Damper | Operation Position | Damper Position | Operation |
|---|---|---|---|
| Air Inlet Control Damper | FRESH | A | Allows fresh air to enter. |
| RECIRCULATION | B | Causes internal air to recirculate. | |
| Air Mix Control Damper | HOT to COOL | C - D | Varies the mixture ratio of cool air and hot air in order to regulate the temperature continuously from Cool to Hot. |
| Air Outlet Control Damper | FACE | E, J | Air blows out of the center registers and side registers. |
| BI-LEVEL | F, J | Air blows out of the center registers, side registers and footwell register ducts. | |
| FOOT | F, I | Air blows out of the footwell register ducts. In addition, air blows out slightly from the center defroster, side defrosters and side registers. | |
| FOOT/DEF | F, H | Defrosts the windshield through the center defroster and side defrosters, while air is also blown out from the footwell register ducts. In addition, air blows out slightly from the side registers. | |
| DEF | E, G | Defrosts the windshield through the center defroster, side defrosters and side registers. |
Mode Position and Damper Operation (Models with Dual Air Layer Type Air Conditioning Unit)
| *1 | Air Inlet Control Damper | *2 | Blower Motor with Fan Sub-assembly |
| *3 | No. 1 Cooler Evaporator Sub-assembly | *4 | Air Mix Control Damper |
| *5 | Front Passenger Side Register | *6 | Center Register |
| *7 | Driver Side Register | *8 | Mode Switching Damper |
| *9 | Front Passenger Side Footwell Register | *10 | Driver Side Footwell Register |
| *11 | Heater Radiator Unit Sub-assembly | *12 | Front Defroster |
| *13 | Driver Side Defroster | *14 | Front Passenger Side Defroster |
| *a | This illustration shows the dampers and air outlets schematically. It will differ from the actual. | - | - |
|
Fresh Air |
|
Recirculated Air |
| Control Damper | Operation Position | Damper Position | Operation |
|---|---|---|---|
| Air Inlet Control Damper | FRESH | A2, B1 | Allows fresh air to enter. |
| RECIRCULATION | A1, B2 | Causes internal air to recirculate. | |
| Air Mix Control Damper | HOT to COOL | C - D | Varies the mixture ratio of cool air and hot air in order to regulate the temperature continuously from Cool to Hot. |
| Air Outlet Control Damper | FACE | E, J | Air blows out of the center registers and side registers. |
| BI-LEVEL | F, J | Air blows out of the center registers, side registers and footwell register ducts. | |
| FOOT | F, I | Air blows out of the footwell register ducts. In addition, air blows out slightly from the center defroster, side defrosters and side registers. | |
| FOOT/DEF | F, H | Defrosts the windshield through the center defroster and side defrosters, while air is also blown out from the footwell register ducts. In addition, air blows out slightly from the side registers. | |
| DEF | E, G | Defrosts the windshield through the center defroster, side defrosters and side registers. |
Air Outlets and Airflow Volume