Home › Engine / Hybrid System › M15A-FXE (COOLING) › COOLANT FLOW
NM36W0E _51 Engine / Hybrid System _087995 M15A-FXE COOLING _0420248 COOLANT FLOW GE GENERAL F

M15A-FXE COOLING  COOLANT FLOW  GENERAL  GENERAL  


OUTLINE


a.

The water-cooled pressure forced circulation method is used as the cooling method.


b.

An electric engine water pump is used to reduce friction losses and weight.


c.

A thermostat is installed on the water inlet side and the bottom bypass is discontinued, which enables the power consumption of the engine water pump assembly (water inlet housing with water pump sub-assembly) to be reduced while maintaining the heater flow rate.


d.

An anti-freezing mechanism is provided that feeds warm water from the cylinder head sub-assembly to the throttle body with motor assembly and EGR valve assembly, stabilizing the operations during extremely cold temperatures.At the same time, the warm water from the cylinder head sub-assembly is also fed to the EGR cooler assembly to cool the EGR gas.


e.

Water pump control that functions via the engine water pump assembly (water inlet housing with water pump sub-assembly) is used for the optimum control of the coolant circulation amount according to the driving conditions.


f.

Because hybrid system is used, when bleeding air during coolant replacement, the mode must be set to maintenance mode. Refer to the Repair Manual for details.


g.

TOYOTA genuine Super Long Life Coolant (SLLC) is used.



SPECIFICATION


a.

Engine Coolant

i.

TOYOTA genuine Super Long Life Coolant (SLLC) is used. The maintenance interval is as shown in the table below:

Coolant Type TOYOTA Genuine SLLC or the Following
Maintenance Intervals First Time 160000 km (100000 miles)
Subsequent Every 80000 km (50000 miles)
Color Pink

HINT:

Similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, and non borate coolant with long-life hybrid organic acid technology. (Coolant with long-life hybrid organic acid technology consists of a combination of low phosphates and organic acids.)



ii.

SLLC is pre-mixed (50% coolant and 50% deionized water), and therefore does not need to be diluted.



b.

Thermostat

Thermostat Opening Temperature 80 to 84°C (176 to 183°F)