Home › Engine / Hybrid System › M15A-FXE (COOLING) › COOLANT FLOW
NM36W0E _51 Engine / Hybrid System _087995 M15A-FXE COOLING _0420248 COOLANT FLOW CO CONTROL F

M15A-FXE COOLING  COOLANT FLOW  CONTROL  WATER PUMP CONTROL  


FUNCTION OF MAIN COMPONENTS


Component Function
Engine Water Pump Assembly (Water Inlet Housing with Water Pump Sub-assembly) Optimizes coolant circulation based on signals from the ECM.
ECM Controls the engine water pump assembly (water inlet housing with water pump sub-assembly) by the engine conditions.
Air Conditioning Amplifier Assembly Transmits the operating state of the air conditioning system and refrigerant pressure to the ECM.


FUNCTION


a.

In M15A-FXE engines, the engine is turned on and off repeatedly by the hybrid system.The engine water pump assembly (water inlet housing with water pump sub-assembly) is used to maintain a stable coolant temperature when the engine is on and cut off the pump motor power when the engine is off, improving fuel economy.


b.

The ECM receives pump motor rotation pulse signals from the engine water pump assembly (water inlet housing with water pump sub-assembly) driver circuit and engine water pump assembly (water inlet housing with water pump sub-assembly) necessary flow rate signals from the air conditioning amplifier assembly, and determines the pump motor rotating speed for obtaining the optimum coolant flow rate according to the driving conditions at this time.