Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM
NM36W0E _51 Engine / Hybrid System _088520 HYBRID / BATTERY CONTROL _0421728 HYBRID CONTROL SYSTEM DE DETAILS F

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  DETAILS  INVERTER  


CONSTRUCTION


a.

The inverter converts the boosted high-voltage direct current of the HV battery into 3-phase alternating current to drive MG1 and MG2.


b.

The activation of the power transistors is controlled by the MG ECU. In addition, the inverter transmits information that is needed for current control, such as the output amperage or voltage, to the hybrid vehicle control ECU via the MG ECU.


c.

The power transistors used in the inverter are Insulated Gate Bipolar Transistors (IGBTs).


d.

Each of the bridge circuits for MG1 and MG2 contains 6 IGBTs, mounted on the high voltage and high current module portion of an Intelligent Power Module (IPM). In addition, a signal processor/protective function processor has been integrated into the control portion of the IPM. The IPM is used to operate the power transistors based on signals from the MG ECU.

W145428E01
3.219,2.917 3.469,3.583 3.469,3.583 3.635,3.583 true 1.708,0.917 1.969,0.917 1.969,0.917 2.521,1.229 true 2.615,0.583 3.073,0.781 0.458,0.198 10 false MG1 5.156,0.583 5.615,0.781 0.458,0.198 10 false MG2 5.313,1.021 5.469,1.219 0.156,0.198 10 false U 4.99,1.021 5.146,1.219 0.156,0.198 10 false V 5.49,1.021 5.646,1.219 0.156,0.198 10 false W 2.458,1 2.615,1.198 0.156,0.198 10 false V 2.771,1 2.927,1.198 0.156,0.198 10 false U 2.948,1 3.104,1.198 0.156,0.198 10 false W 0.281,0.802 1.823,1.01 1.542,0.208 10 false Inverter Current Sensor 2.229,3.365 3.917,3.563 1.688,0.198 10 false IPM for MG1 4.729,3.365 6.417,3.563 1.688,0.198 10 false IPM for MG2 3.542,3.917 5.083,4.125 1.542,0.208 10 false Inverter 3.688,3.5 4.302,3.698 0.615,0.198 10 false IGBT