Home › Engine / Hybrid System › STOP AND START › STOP AND START SYSTEM › from 2020.07
NM36W0E _51 Engine / Hybrid System _091800 STOP AND START _0434050 STOP AND START SYSTEM CO CONTROL F

STOP AND START  STOP AND START SYSTEM  CONTROL  ELECTRIC OIL PUMP FOR CVT CONTROL  


SYSTEM CONTROL


a.

Because the engine stop and start ECU operates the oil pump with motor assembly during idle stop, a stable CVT oil pressure is ensured, enabling a smooth vehicle start.

W130859E05
5.573,1.427 6.885,2.208 1.313,0.781 0.708,1.333 1.167,1.531 0.458,0.198 10 false ECM 2.063,0.542 3.438,1.094 1.375,0.552 10 false Engine Stop and Start ECU 2.292,1.479 3.198,1.938 0.906,0.458 10 false Backup Boost Converter 3.875,0.906 5.177,1.531 1.302,0.625 10 false Oil Pump with Motor Assembly Rotation Frequency 3.688,1.896 5.417,2.427 1.729,0.531 10 false Oil Pump with Motor Assembly Operation Signal (Duty Signal) 5.74,1.479 6.75,1.969 1.01,0.49 10 false Oil Pump Motor Driver 0.5,2.458 4.167,2.656 3.667,0.198 10 false : CAN Communication Line 5.604,0.604 6.885,1.094 1.281,0.49 10 false Oil Pump with Motor Assembly


b.

Engine stop and start ECU actuates the oil pump with motor assembly when it receives an engine stop signal and the following condition is met. The oil pump with motor assembly will stop operating when the engine automatically starts and the engine speed exceeds a specified value.

Oil Pump with Motor Assembly Operation

○: Operating

-: Idle stop is disabled

Shift Position P R N D B/M
Brake On (applied) ○ - - ○ -
Brake Off (not applied) ○ - - - -

Oil Pump with Motor Assembly Operating Condition
Item Condition Remarks
CVT Oil Temperature 25°C to 100°C (77°F to 212°F)
·

Detected from the oil temperature sensor in the CVT.

·

However, once this range has been reached, operation will then be permitted in the range from 22°C to 111°C (72°F to 232°F)